Re-assigning the remote control

The device can only be operated with a
single, assigned remote control.
Press the <+> button on the remote control
and the <up> button on the lateral control
panel simultaneously for approx. 30 seconds
until [Pairing ok] appears on the display.
Result
✓ The shower toilet can be controlled by remote
control.
40

Testing automatic flush actuation

The following test must only be performed if the
device is fitted with the optional interface module for
flush actuation (art. no. 147.039.00.1).
Prerequisite
– The automatic flush actuation has been fully
installed.
– The automatic flush actuation has been
switched on in the [Basic settings]main menu.
– All plug connections are connected correctly.
Apply a load to the WC seat for more than
10  s econds. Then remove the load.
Result
✓ A flush is actuated after around 5  s econds.