7.2 Sensors
This menu allows you to set the various sensors to
optimize consumption.
7.2.1 Presence sensor
This function allows the radiator to pick up whether or not people are in the space, and automatically regulate the heating level,
in order to optimise comfort and energy saving.
Thanks to this function, which can only be activated in Comfort mode, the radiator continuously monitors the room and, if no
people are detected, it reduces the comfort temperature set as follows:
Period
of absence
60 min
90 min
120 min
38 hours
The reduction is temperature always relates to the comfort temperature. If the radiator is in Eco or Anti-freeze mode, no change
in temperature to be maintained in the room will be observed.
Should someone be detected in the room for at least 10 consecutive minutes, the temperature is automatically returned to the
comfort temperature set, without any reduction. The same happens if, while the temperature required is being reduced, due to
an absence of people being detected in the room, any of the radiator key is pushed.
Important:
Correct operation of this function may depend on where the radiator is positioned in the room. To choose the best installation
position, bear in mind that the sensor detects movements within the area indicated in figure 9, and that no objects must be in
its way. Presence detection is also more effective when people move in front of the sensor that when they move towards it.
7.2.2 Open window sensor
This function makes it possible to detect an open
window and automatically activate the Anti-freeze
operating mode.
If a sudden reduction is temperature is detected
when the radiator is operating normally, anti-freeze
mode is activated automatically to reduce energy
wastage. On the display the window and anti-freeze
symbols flash.
7.2.3 Sensibility
With this function it is possible to adjust the sensi-
bility of the presence sensor. If you feel that it does
not detect people adequately even when they are
present, increase the sensitivity if, on the contrary,
presence is indicated even when there is no one in
the room, decrease it. This adjustment is particularly
important for the correct functioning of the Auto fun-
ction which adjusts the room temperature according
to your habits.
MENU
Mode
Sensors
Information
Settings
Stand-by
Reduction of the
comfort temperature
1,0°C
2,0°C
3,5°C
Anti-freeze activated 7±3°C
SENSORS
Presence
Open window
Sensibility
27
SENSORS
Presence
Open window
Sensibility
Indication
on the display
The presence sensor and comfort
mode symbols flash.
Reinstating normal operation does
not occur automatically, but must be
activated by pushing the
Important:
Correct operation of this function may
depend on where the radiator is posi-
tioned in the room, the presence of
draughts, the outside temperature,
and how long the window stays open.
SENSIBILITY
Sensibility of the
presence sensor
Medium
key.