OPERATION
Cleaning, care and maintenance
Locking the temperature selector
1 Retainer for contact pieces
2 Contact piece placed in the setting range
f Remove one of the contact pieces from its retainer using a
f
cutting tool and position it as shown.
Limiting the setting range
f Remove both contact pieces from their retainer using a cut-
f
ting tool.
f Position the contact pieces, with one at each end of the re-
f
quired setting range.
f Replace the temperature selector.
f
5.
Cleaning, care and maintenance
Note
Avoid abrasive or corrosive cleaning products.
Clean the surfaces when cold, using a soft cloth and ordinary
cleaning products.
16
| BHE Style
6.
Troubleshooting
1
Problem
The heated air smells
unpleasant.
2
The appliance does
not heat up.
The appliance heats
continuously.
The 24 h automatic
function is not work-
ing.
The elements at the
very top and bottom
don't get as warm as
the rest of the appli-
ance.
Dirty marks appear
on the wall around
the appliance.
The boost function is
terminated prema-
turely
If you cannot remedy the fault, notify your qualified contractor.
To facilitate and speed up your request for assistance, provide the
number from the type plate (000000-0000-000000).
The type plate is located at the bottom, on the right hand side of
the appliance.
Cause
Remedy
This can be caused by
The smell will dissipate within
dust during commis-
a few minutes.
sioning.
The MCB/fuse has re-
Replace the fuse/reset the
sponded/blown.
MCB.
The temperature sensor
Call your qualified contractor.
is damaged (heating
indicator flashes 3 times
on start-up)
The mains voltage to the
Switch the appliance off. Call
appliance is too high
your qualified contractor.
(heating indicator flash-
es 5 times on start-up).
The appliance is subject
Remedy the cause of the
to a continuous draught.
draught.
The temperature setting
Set the required room tem-
was changed.
perature at the temperature
selector.
There is a fault with the
Disconnect the appliance
power supply.
from the power supply for
10 minutes and then switch it
back on. If the problem occurs
regularly, arrange for your
power supply utility to check
the power supply.
There was a power
Set the 24 h automatic func-
failure.
tion again.
The clocks have changed
Set the 24 h automatic func-
to summer/wintertime.
tion again.
The elements at the
The heating medium expands
top are not completely
when it gets warm. It takes
filled.
a little longer for these ele-
ments to heat up.
Dirty marks are caused
Avoid contaminating the in-
by contaminated air
door air.
(candles, cigarette
smoke, poor ventilation,
etc.).
The room temperature
Switch the appliance off. Wait
is too high. For safety
at least 10 minutes before
reasons, the appliance
switching the appliance back
has automatically
on.
switched off the rapid
heater prematurely.
www.stiebel-eltron.com