installation

commissioning

6.2

alternative installation methods

6.2.1 installation with connection to a twin wash basin
6.2.2 installation with connection of a second draw-off point
7.
commissioning
f check the safety valve and the non-return valve (see chapter

„Maintenance").

7.1

setting, pressure reducing valve

For setting range, see chapter „Specification/Data table".
f Turn the slotted screw anti-clockwise to reduce the pressure
or clockwise to increase it.
8.

troubleshooting

problem
cause
During heating, no water
The non-return valve is
drips from the safety
faulty.
valve.
After heat-up has ended,
The safety valve is con-
water drips from the
taminated.
safety valve.
10
| svmt
9.
For later maintenance work on the installation, you can shut off
the supply line to the safety assembly.
1 Pressure gauge connection
2 Safety valve
3 Pressure reducing valve
4 Test connection, non-return valve
5 Shut-off valve, cold water inlet
6 Shut-off valve, cold water inlet, open
7 Shut-off valve, cold water inlet, closed
9.1.1 testing the safety valve
f For safety reasons, check the safety valve twice each year.
f Turn the vent cap two or three times anti-clockwise.
During heat-up, expansion water must drip into the drain outlet
[GB: Tundish].
No water must drip out after heat-up has terminated.
9.1.2 cleaning / replacing the safety valve
f Rotate the shut-off valve 90° upwards to close the cold water
f Open the tap to depressurise the water heater.
f Undo the safety valve.
f clean the seat and gasket.
f Refit the safety valve.
f Replace the entire safety valve if a repair becomes necessary.
f remedy
check the function of the
non-return valve and
change it, if required .