4.7 Advanced settings
WARNING:
This operation is used to assist servicing and future repairs.
The default settings should only be modified by an experienced
professional person.
The system's settings can be checked and adjusted via the remote control by
following these steps
Step 1 : Keep pressing
Step 2 : Press
and
Step 3 : Press
to select the setting to be modified.
M
Step 4 : Press
and
Step 5 : Press
to set the new value.
M
Step 6 : Press
to return to the main screen.
Parame-
Meaning
ters
F1
Heating setting temperature
F2
Cooling setting temperature
F3
Mute Setting temperature
F4
Set temperature in automatic mode
F5
Linkage switch function
F6
Return differential temperature in heating
mode
F7
Return differential temperature in cooling
mode
F9
Return differential temperature in automatic
mode
F10
Upper heating temperature
F11
Lower cooling temperature
F21
Pump interval running time
MV-1058-1059-04-2022 . swim-fun.com © All rights reserved Swim & Fun A/S
M
3s until you enter the settings verification mode.
for see the parameters.
to adjust the setting value.
Range
Unit
20~80
°C
5~30
°C
20~80
°C
10~60
°C
0~2
0~10
°C
0~10
°C
0~10
°C
20~80
°C
5~30
°C
0~120
Min