4.6 Status values

The system's settings can be checked and adjusted via the remote control by
following these steps
Step 1 : Keep pressing
Step 2 : Press
Step 3 : Press
Parameters table
Parame-
ters
A
B
C
D
E
F
G
H
L
J
O
P
U
MV-1058-1059-04-2022 . swim-fun.com © All rights reserved Swim & Fun A/S
122
M
1s until you enter the settings verification mode.
and
for see the parameters.
to select the setting to be viewed.
M
Indication
Inlet water temp.
Coil temp.
Ambient temp.
Inlet water temp. setting
value (automatic)
Inlet water temp. setting
value (cooling)
Inlet water temp. setting
value when (heating)
Interval time of defrosting
Exit time of defrosting
Heat pump restart temp.
difference
Power off protection
Ambient temp. of antifreeze
protection
Coil temp. of entering
defrosting
Coil temp. of exiting
defrosting
Setting
Remark
range
-19~99°C
-19~99°C
-19~99°C
8°C~40°C
30°C
8°C~28°C
12°C
10°C~40°C
27°C
10~80Min
40 Min
5~30Min
8 Min
1°C~10°C
2°C
0~1
1(Yes)
0°C~15°C
-5°C
-19°C~0°C
-3°C
1°C~30°C
20°C
Measured
Measured
Measured
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable
Adjustable

Advertenties