operation for a longer period of time, and especially during the winter season.
• When the heat pump is being prepared for winter storage it is recommended to cover
the heat pump to or keep it indoors where it will be protected from frost.
• At startup, make sure that the system is fully filled with water before the unit is switched
on.
• In normal operation, the air being sucked in will be cooled and water can/will condense
on the ribs of the evaporator and run out of the base of the unit. It is quite normal that
there will be condensation from the heat pump. It is not a leak or a fault with the device.
High humidity can lead to several litres of water being condensed per day.
• The refilling of gas must be performed by a professional with an R32 operating license.
6.

Troubleshooting

Fault condition
Low air temperature pro-
tection
Water temperature sensor
error
Air temperature sensor error
Low pressure switch alarm
6.1 Electrical circuit

Wiring diagrams

Heat Splasher 1295
MV-1295-1296-1297-10-2020 . swim-fun.com © All rights reserved Swim & Fun Scandinavia ApS
Code
Reason
P0
Air temperature is too low
P1
Water temperature sensor
open circuit or short circuit.
P2
Air temperature sensor
open circuit or short circuit.
EL
Low pressure switch
disconnected
Heat Splasher 1296 / 1297
Solution
Can only be used when the air
temperature rises above 12 °C
Water temperature sensor needs
to be replaced. Contact dealer
Air temperature sensor needs to
be replaced. Contact dealer.
Contact dealer