Download Print deze pagina

EdilKamin SALLY Installatie, Gebruik En Onderhoud pagina 34

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 112
V
fi g. 13
fi g. 14
fi g. 15
INSTALLATION
SMOKE OUTPUT
SALLY is designed for the connection of the smoke output at
the back or top.
The stove is delivered ready for the output of the fl ue from the
back (Fig. 13).
TOP SMOKE OUTPUT CONNECTION
Fig. 13-14
• Remove the right metal side (A - Fig. 11), by means of the
three screws (V) on the back of the stove.
• Remove the closing cover (Q - Fig. 14)
Fig. 15-16
• Remove the elbow joint (X - Fig. 15) complete with band
from the smoke extractor unit and reposition it with the con-
nection point to the smoke output pipe (not provided), directed
Q
upwards.
• Install the smoke output pipe (not provided) using the band
(not provided) on the elbow joint.
• Position the rosette provided (U - Fig. 16).
AFTER COMPLETING THE CONNECTION OF THE
A
SMOKE OUTPUT PIPE TO THE FLUE, REPLACE THE
METAL SIDE.
X
fi g. 16
- 34
-
U

Advertenties

loading

Deze handleiding is ook geschikt voor:

Sally plus