CLEANING, MAINTANANCE & STORAGE
― ―
WARNING: ALWAYS TURN THE HEATER OFF, UNPLUG THE POWER CORD FROM THE
ELECTRICAL OUTLET AND ALLOW THE APPLIANCE TO COMPLETELY COOL DOWN
BEFORE HANDLING OR CLEANING IT.
CAUTION: DO NOT ALLOW WATER OR OTHER LIQUIDS TO RUN INTO THE INTERIOR
OF THE HEATER, AS THIS COULD CREATE A FIRE AND/OR ELECTRICAL HAZARD.
CAUTION: DO NOT USE ANY ABRASIVE CLEANERS OR SOLVENTS, AS HEATER DAM
AGE WILL OCCUR.
•
Clean the exterior surface of the heater by wiping it with a soft, damp cloth. Dry the heater
with a soft clean cloth.
•
Clean the air inlet and outlet grills regularly with a vacuum cleaner, using the brush attachment
to avoid any dust build-up.
•
To store your product out of season, we recommend using the original or similar size box.
•
Store the heater in a safe, clean and dry place when not in use.
•
To ensure adequate air circulation keep vents at the rear of the heater free of dust. Do not
disassemble the heater to remove dust.
MINI CERAMIC SPACE HEATER | MODEL PB-H12
Heat output
Nominal heat out-put
Minimum heat output (indicative)
Maximum continuous heat output
Auxiliary electricity consumption
At nominal heat output
At minimum heat output
In standby mode
Type of heat input, for electric storage local space heaters
only (single select)
Manual heat charge control, with integrated thermostat
Manual heat charge control with room and/or outdoor
temperature feedback
Electronic heat charge control with room and/or outdoor
temperature feedback
Fan assisted heat output.
5 | English
Symbol
Value
P nom
2.0
P min
1.0
P max,c
2.0
el max
N/A
el min
N/A
el SB
0
Unit
kW
kW
kW
kW
kW
kW
Unit
No
No
No
No