To prevent from electric shock, make sure that no electrical
o
device is connected on the circuit to be tested before RCD test .
Check for correct wiring of all shockproof sockets on the branch
o
circuit under the monitoring of the RCD to be tested .
1 . Plug the product into the shockproof socket, which is under the
monitoring of the RCD to be tested . Verify that the shockproof
socket's wiring is shown as CORRECT .
If the wiring is shown as CORRECT Please reverse: Unplug
the product from the shockproof socket . Turn the product by
180° (see fig . C) .
Plug the product into the shockproof socket again . Check if
wiring is shown as CORRECT (see "Testing socket wiring") .
2 . Press RCD TEST
upstream RCD (IΔ = 30 mA):
Action
The RCD trips .
20 GB/IE/NI
to check the tripping function of an
5 ]
[
Result
Tripping function is working .