Download Inhoudsopgave Inhoud Print deze pagina

Safety Notes; Installation Instructions; Technical Data - Hansgrohe Ecos XL CoolStart 14044000 Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen
  • NL

Beschikbare talen

  • DUTCH, pagina 7

Safety Notes

Gloves should be worn during installation to prevent
crushing and cutting injuries.
The product may only be used for bathing, hygienic
and body cleaning purposes.
The hot and cold supplies must be of equal
pressures.

Installation Instructions

• Prior to installation, inspect the product for transport
damages. After it has been installed, no transport or
surface damage will be honoured.
• The pipes and the fixture must be installed, flushed
and tested as per the applicable standards.
• The plumbing codes applicable in the respective
countries must be observed.
• The drain valve must only be used as intended. It is
not allowed to attach other objects to the drain
valve, for example a semi-pedestal.
• 14044000 / 14083000: The drain valve may only
be installed in basins with an overflow opening.
• If the instantaneous water heater causes problems
or if you wish to increase the water flow, the
EcoSmart
(flow limiter) located behind the aerator
®
can be removed.

Technical Data

This mixer series-produced with EcoSmart
(flow limiter)
Operating pressure:
Recommended operating pressure:
Test pressure:
Hot water temperature:
Recommended hot water temp.:
Thermal disinfection:
The product is exclusively designed for drinking water!
4
max. 1 MPa
0,1 - 0,5 MPa
1,6 MPa
(1 MPa = 10 bar = 147 PSI)
max. 70°C
max. 70°C / 4 min
Assembly (see page 31)
English
Symbol description
Do not use silicone containing acetic acid!
Adjustment (see page 33)
To adjust the hot water limiter. Using a hot water limiter
in combination with a continuous flow water heater is
not recommended.
Dimensions (see page 36)
Flow diagram (see page 36)
with EcoSmart
without EcoSmart
Cleaning (see page 35)
Spare parts (see page )
Special accessories (order as an
extra)
• special tool #58085000 (see page 31)
• Installation putty (see page 32)
Operation (see page 34)
• Hansgrohe recommends not to use as drinking water
the first half liter of water drawn in the morning or
after a prolonged period of non-use.
®
• After periods of prolonged non-use, but at least
every third day, the fittings must be opened with the
handle in hot and cold position to prevent stagnation
in the connecting lines. Let the water run until the
water temperature is constant.
Test certificate (see page 40)
65°C
®
®

Advertenties

Inhoudsopgave
loading

Deze handleiding is ook geschikt voor:

Ecos xl 14083000Ecos 230 14088000

Inhoudsopgave