STANDARD LIQUID/VAPOR RECOVERY PROCEDURE
1.
Make sure this recovery machine is in good operating condition.
2.
Make sure all connections are correct and tight.
3.
Open the liquid port of the storage tank.
4.
Make sure the MODE valve is set on RECOVER.
5.
Open the output port of the recovery machine.
6.
Open the liquid port on your manifold gauge set; opening the liquid port
will remove the liquid from the system first. After the liquid has been
removed, open the manifold vapor port to finish evacuating the system.