f) test mode
Press and hold the "MODE" button (> 1 second) and then select the test mode by pressing
the "MODE" button again..
Press "CURRENT" to select the charging current (200, 500, 700mA). The discharging
current (100, 250, 350mA) is half of the selected discharging current.
Press "DISPLAY" button to scroll through different displays, charging current (mA), battery
voltage (V), accumulated capacities (mAh) or time elapsed (hh:mm).
Stage in charging
mode
During charging
During discharging
During second
charging
During trickle
charging
g) tickle charging
After the rechargeable battery is fully charged in any of the operating modes, the charger
will send impulse form of current to the rechargeable batteries to maintain the fully charged
level. This mode is automatically launched after rechargeable batteries are fully charged
and kept at the charging unit. The "Full" icon will be displayed on the display.
* The timer will be resumed and counted from 00:00 again after the time elapsed is longer
than 20 hours. (For example, 1:45 will be shown after the battery has been refreshed for
21 hr and 45 min.)
20
All manuals and user guides at all-guides.com
Current (mA)
Voltage (V)
Charging current
Discharging
current
Instantaneous
battery voltage
Charging current
Trickle charging
current
Capacity
Time (hh:mm)*
(mAh/Ah)
Charging time
"--- mAh"
elapsed
Discharging
"--- mAh"
time elapsed
Second
Capacity
charging time
determined in
elapsed
Discharging
discharging
time elapsed