If the air humidity is set to less than 30%, the device will continuously dehumidify.
The display will show "CO".
Press the ON/OFF button again in order to switch the device off. The device will
come to a halt and all of the lights will go out. The device will retain its settings as
long as the power is connected. If you remove the plug from the socket, the settings
will be deleted from the system unless the memory function has been activated.
Note:
 If the set humidity is higher than the actual humidity, the device will not come on.
 If you are dehumidifying, the fan motor and the compressor will run for at least
three minutes before the compressor starts. The compressor may not be restarted
within three minutes of switching the device off. It is, therefore, possible that the
motor will not immediately respond to being turned off or on!
 When the temperature is low, keep an eye on whether the device needs to defrost.
When defrosting, the relevant light will come on and the fan will run but the
compressor will automatically switch off.
 If you press the memory button, the system will retain the set humidity level even if
there is a power failure. Once the power supply has been restored, the device will
start to work according to the previously entered settings.
 The display will show a humidity level of 30% to 90%.
 Remove the plug from the socket if you do not plan to use the device for an
extended period.
 Only LO50: If the water reservoir is full, the light will come on and the compressor
and fan will automatically shut down. You will also hear a beep. If you do not drain
the reservoir, the beep will be repeated every 5 minutes. Only once the reservoir
has been emptied can the device be used again.
 Only LO50: You can install a continuous drain by removing the reservoir, taking
the rubber bung out of the base of the reservoir and connecting a hose to this
outlet. Then replace the reservoir and run the hose from the device (downwards)
to a suitable drainage point.
USE
 In order to avoid damaging the compressor, never place the dehumidifier on a
slope of over 45°.
 The device works between 5°C and 32°C.
 When being used, the compressor will emit heat which can increase the ambient
temperature by between 1 and 3°C. This is perfectly normal.
 If the indoor temperature is lower than 10°C and air humidity is pretty low, you will
not need to use the device.
 Ensure that there is at least 10 cm of free space between the air inlet and the
outlet opening and any solid objects, e.g. a wall.
 Try to ensure that the room is as well sealed as possible in order to improve the
dehumidification result.
CLEANING
Too much dust on the filter will impact upon the device's ability to dehumidify. Clean
the filter regularly (at least once a month); if the device is placed in a dusty
environment, you should clean it weekly or even daily. To do so, remove the front
panel and take the filter out. Remove the loose dust by carefully knocking the filter.
Then vacuum the filter gently or wash it in lukewarm water with a little, mild soap.