Chapter 2, OPERATION
4. Prior to use
Step 1: Open the valve(s)
Screw the valve on the top of the removable tank open
or open the valve for the external fuel tank and the
fire safety valve of the heater (if present).
Step 2: Start the fuel supply
Carefully press the red unlocking button for one sec-
ond to release the float in the fuel receptacle.
The fuel receptacle only has to be unlocked when the
heater is activated for the first time or after it has run
out of fuel, or if the heater has not been used for an
extended period of time. Unlocking may also be
required if the fuel inlet pressure exceeds 2.5 psi
(± 0.17 bar). In this case, a pressure reduction valve
must be installed.
Step 3: Adjust the clock
Important: The clock on the heater must always be set
to the correct time.
A. Switch the time selector switch to "CLOCK SET"
B. Press the "HOUR" and the "MINUTE" buttons to
adjust the hours and minutes. Pressing the "HOUR"
or "MINUTE" button once will adjust the time by
one unit (hours or minutes respectively). Holding
the button down accelerates the adjustment of the
time display.
All clock and timer settings are deleted if the power is
cut off for a period longer than 10 seconds. The infor-
mation display flashes "PM 12:00" when the heater is
switched off. The clock and timer now have to be
reprogrammed.
C. Set the timer switch to the "NORMAL" setting after
completing the clock adjustment. The current time
is then displayed on the digital indicator.
5. Igniting the heater
The heater is operated directly by the user. However,
the heat yield is controlled automatically in accordance
with the room temperature registered by the tempera-
ture sensor.
Step 1: Switch the heater ON
43
All manuals and user guides at all-guides.com
Press the ON/OFF button. The current room tempera-
ture and the set temperature are displayed on the
information display.
The ON/OFF light starts to flash, after which the heater
will switch on.
Note: (*) The start-up time depends on the room tem-
perature.
After 9-15 minutes, the heater will automatically select
the correct operating mode and the ON/OFF button will
now be illuminated continuously.
Room temperature:
under 0°C
0°C - 15°C
15°C
If no flames are visible after the start-up period, the
heater will deactivate and then restart automatically. If
flames are still not detected, the heater will deactivate
and will have to be restarted manually (error code E-2
on the information display).
Step 2: Setting the room temperature
The temperature setting can only be adjusted, when the
heater is burning. Use the adjustment buttons to adjust
the temperature. First press either of the two buttons to
switch on the function (the TEMP light next to the infor-
mation display will start blinking). Next, adjust the tem-
perature using the button on the right ( min.) to set the
temperature to a higher setting and the button on the
left ( hour) to lower the temperature. Press once to
increase the value one step. After approximately 10 sec-
onds the light will stop blinking and setting will be
locked. The available temperature settings range from
10°C minimum to 32°C maximum. When the heater has
been unplugged (or after a power failure), the tempera-
ture will reset to the factory setting of 20°C.
The operating mode is automatically controlled in accor-
dance with the room temperature detected by the room
temperature sensor. The heater works in the "HIGH"
operating mode until the room temperature has reached
the desired level.
When the room temperature reaches the chosen setting.
the heater automatically switches to the "MED" or
"LOW" operating mode in order to maintain the desired
temperature.
11 minutes
9 minutes
8.5 minutes