Chapter 1, INSTALLATION
8. Make sure the position of the heater is level by using
the plumb bob located at the right side of the heater.
The plumb bob weight should be within the circle. If
Good
Weight
Circle
Bad
Plumb bob as viewed from above
Fig. 13
Fig. 13
Choose a location for the sensor that is not in the path of direct sunlight, drafts or the flow of
w
9. A room temperature sensor is provided with a 2.5 m
long extension wire. It is located on the rear of the cabi-
net. Make sure that the extension wire is not touching
the exhaust pipe. The room temperature sensor can be
installed either with the self adhesive tape on the back
or with a wood screw provided with the sensor depend-
(a) Self Adhesive Tape
Peel off the protective tape on the back of the sen-
sor and expose the adhesives. Place the sensor on
the desired location on the wall and press down.
(b) Wood Screw
Screw down the wood screw provided with the
heater into the desired location on the wall. Hook
the back of the room temperature sensor.
10. After installation is completed, secure heater to the
wall with the wall brackets provided with the heater.
Make sure the heater is parallel to the wall (See Fig.
15).
11. Before ignition, recheck the following:
a. All connections are tight and firm.
b. The heater and the flue pipe areas are free of any
materials.
c. The heater is level and parallel to the wall.
All manuals and user guides at all-guides.com
the plumb bob weight is not within the circle, adjust
the heater legs until the plumb bob weight is within
the red circle (See Fig. 13 & 14).
Fig. 14
ing on the type of surface chosen for installation.
(a)
Fig. 15
NOTE: Choose a location for the sensor that is
not in the path of direct sunlight, drafts or the
flow of warm air from the heater.
(b)
38