7.
Zero/Relative Button - Once this button is pressed, the current reading shall be set to zero and be used as a zero reference
value for all other subsequent measurement. This fucntion will be disabled when MAX/MIN function is enabled.
8.
LCD - This is a 3 3/4 digit Liquid Crystal Display with maximum indication of 3999. Function symbols, units, bargraph, sign,
decimal points, low battery symbols, max/min symbols, and zero symbol are included.
9.
Low Battery Symbol - When this symbol appears, it means the battery voltage drops below the minimum required voltage.
Refer to Section V for battery replacement.
10. Zero/Relative Symbol - When this symbol appears, it means a reference value has been subtracted from the actual reading.
The reading shown is a offseted value. Press and hold the zero button for 2 seconds to disable this function.
11. Data Hold Symbol - Once the hold button is pressed, this symbol appears on LCD.
12. Bargraph - Bargraph has forty segments. It displays segments proportional to the actual reading. Each segment represent one
count.
13. Max/Min Hold Symbol - Once the max/min button is pressed, either MAX or MIN shall be displayed on LCD
14. Continuity Symbol - If ohm and continuity function is selected, this symbol shall appears on LCD.
15. Units Symbols - Once a function is selected, corresponding unit (V, Ω, A, or Hz) shall be displayed on LCD.
16. VΩ Input Terminal - This terminal is used as input for voltage, or ohm/continuity measurements.
17. COM Terminal -This terminal is used as common reference input.
18. Hand Strap - Put your hand through the hole of hand strap to avoid accidental drop of the clamp meter.