The lower opening should be located at floor level ( to
allow any leaking gas to escape to the outside).
The ventilation of the cooling unit can also be done via
two openings in the wall of the caravan (fig. 7 b).
Fresh air enters through the lower opening and warm air
is discharged through the upper one.
The upper ventilation opening should be located above
the condenser, as high as possible, to ensure good
ventilation.
The lower opening should be located at floor level ( to
allow any leaking gas to escape to the outside).
The openings in the caravan wall must be fitted with
suitable grilles with sufficient heat resistance. These
should have a free flow-through area of at least 300 cm2.
Please observe that fly netting behind the grilles can
reduce the area by as much as 50%.

LP GAS CONNECTION

The refrigerator is designed for operation on LP gas, the
pressure of which must 28 mbar for Butane and 37 mbar
for Propane. Check that this is stated on the data plate.
The refrigerator is not designed for operation on
town gas or natural gas.
CAUTION! CHECK THAT THE GAS SUPPLIED
TO THE REFRIGERATOR IS AT THE CORRECT
PRESSURE. SEE THE REDUCING VALVE ON
The gas installation should only be carried out by a
person experienced in gas fitting. It is recommended that
the gas pipe feeding the refrigerator is so arranged that
it is possible to turn off the supply of the refrigerator.
It must be of a type approved for use with continuously
operating bottled gas appliances, and have threaded
compression connections throughout. PUSH-ON CON-
NECTIONS MUST NOT BE USED (We do not recom-
mend the use of "rubber" type flexible tubing for
connecting permanently operating appliances of this
type in the United Kingdom). All connectors etc. should
be off a type specifically designed for the type and
diameter of the connection pipe used, and screwed
joints should be sealed with a joining compound appro-
ved for use with bottled gas.
The gas supply pipe should be connected to the gas inlet
off the gas control valve by means off a suitable threaded
coupling.
In making the connection to the refrigerator, a union gas
cock of an approved type bottled-gas must be incorpo-
rated in the supply line in a position which is readily
accessible to the user. For eventual servicing purposes,
the union should be on the outlet side of the cock and
the pipework should be positioned so as not to prevent
the refrigerator from being readily withdrawn.
On completion of installation, the system must be
pressure tested by a qualified technician.

ELECTRICAL CONNECTION

The electrical installation must be carried out in a proper
and durable manner, taking into account all relevant
regulations and codes of practice.
As the colours of the wires in the mains lead of this
appliance may not correspond with the coloured mark-
ings identifying the terminals in your plug, proceed as
follows:
- the wire which is coloured green and yellow must be
connected to the terminal in the plug which is marked
with the letter E or by the earth symbol & , or
coloured green or green and yellow,
- the wire which is coloured blue must be connected to
the terminal which is marked with the letter N or
coloured black,
- the wire which is coloured brown must be connected
to the terminal which is marked with the letter L or
coloured red.
WARNING- THIS APPLIANCE MUST BE EARTHED
IMPORTANT
The wires in this mains lead are coloured in accordance
with the following code:
- green/yellow:
earth
- blue:
neutral
- brown:
live
Your appliance is already fitted with a 13 amp.(B.S. 1363)
fuse plug incorporating a 3 A fuse. If it does not fit your
socket the plug should be cut off from the mains lead
and an appropriate plug fitted.
Throw away the cut off plug; do not insert it in a 13 A
socket-outlet elsewhere in the house as this could cause
a shock hazard.
The fuse cover must be re-fitted when changing the fuse.
Never use the plug without the fuse cover.
The appliance must be protected by a 3 amp. fuse, ASTA
approved to B.S. 1362.
240 V Supplies.
Check that the voltage stated on the data plate is the
same as the mains voltage in use (240 V).
Plug the 240 V refrigerator power cord into an easily
accessible wall socket.
sharp parts of the refrigerator.
12 V and "D+" Connection
The 12 V connection of the refrigerator is shown in
fig. 8. The (+12 V and (-) pole have to be connected
directly to the vehicles battery. Do not use the chassis
for the return lead. The battery cable must not be con-
nected to a voltage controller or similar device as the
AES itself monitors the battery voltage.
A relay cutting out 12 V operation when the ignition key
is turned off. is not recommended.