Download Print deze pagina

Ventilation Of The Unit - Electrolux RM4605 Handleiding

Advertenties

Beschikbare talen

Beschikbare talen

1
FIG. 5
Install the two screws in the top frame, the holes are
accessible from beneath.
After the two screws have been installed, seal the holes
in the top frame with a piece of tape.
Replace the top decoration panel. Be careful not to pinch
the wires behind the panel. Make sure the tabs snap
back into the holes in the hinge plate.
ventilation
Ventilation heights
Model
Minimum ventilation heights in mm.
At high ambient temperatures the refrigeration unit will
only perform adequately when properly ventilated. The
ventilation passage at the rear of the recess, between
the outer wall of the vehicle and the refrigerator must be
24
FIG. 6
C: Two screws installed in the rear base. See fig. 6.
Failure to follow the sequence in securing the refrigerator
in the enclosure can cause leakage between the frame
and cabinet. Any space between the counter, storage
area or ceiling and top of the refrigerator greater than
40 mm should be blocked. The heat produced at the rear
of the refrigerator will become trapped in this space,
making the top of the refrigerator hot and reduce the
efficiency of the refrigerator.

VENTILATION OF THE UNIT

completely sealed off from the interior of the caravan.
Neither flue gas nor (cold) air from the ventilation open-
ings in the wall of the caravan (outer wall of the ventila-
tion passage) must be able to pass into the interior of
the caravan.
The side walls of the shaft should be thermally insulated
to prevent condensation and cold draughts. Shaft wall
sections located above and below the exhaust gas vent
must not be made of flammable materials.
Proper installation requires one lower fresh air intake
and one upper exhaust vent (fig. 7a).
These should have a free flow-through area of at least
300 cm2.
Fresh air enters through the lower opening and warm air
is discharged through the upper exhaust vent.
/Minimum
ventilation
height
FIG. 7b
A wood strip must be
in place across the
upper opening of the
enclosure.

Advertenties

loading

Deze handleiding is ook geschikt voor:

Rm4805