Setting of the end positions
4.5. Setting of the end positions with setting switch/switch
Note:
Settings with a wired switch are only possible in semiautomatic setting mode.
When connecting the setting switch, consider the following:
Caution! Risk of injury through an electric shock!
Connection only when deenergised!
Warning!
The 4 wires in the setting switch cable must be connected to the motor wiring cable
according to their colours.
UP = brown
DOWN = black
N = blue
PE = yellowgreen
SELVE setting switch (item no. 290103)
LED indicates connection in correct phase sequence
Pushbutton E is the setting pushbutton
Pushbutton for moving the motor up and down
27
EN
EN