EN Setting of the end positions

4. Setting of the end positions

4.1. Delivery status

In the SELVE delivery status no end positions or transmitters are programmed into
the radio motor! In this state, the motor can be operated in deadman's operation only.
Safety functions are deactivated at delivery and will only become active after both end
positions are set.
In delivery status the SEM Plus­RC is in semi­automatic programming mode. This will
be signalized by a short up and down movement when connected to mains.

4.2. Setup functions

The end positions setting of a SELVE radio motor is possible via:
• the setting switch for radio motors (item no. 290109) or with
• any standard switch (only in semi-automatic mode) or with
• any standard commeo or iveo transmitter.

4.3. Mechanic requirements

The awning always has to be equipped with a a fixed upper end limit.
Caution:
There is no automatic setting of the lower end limit when using the SEM Plus­RC. The
lower end limit has always to be run­up to or also set.

4.4. Selection table for settings

Setup-mode/end positions in operation
Semi­automatic setup­mode
bottom position, top stop with release*
Manual setup­mode
bottom position, top stop with release*
Manual setup­mode
bottom position, top stop without release
* Both setting procedures are leading to the same result.
Setting switch
4.5.1. (page 28)
4.5.2. (page 29)
4.5.3. (page 30)
26