4 OPTIONAL
Power limitation induction hob
The hob is equipped with a power limitation. If the power
level on two zones exceeds the maximum power, the
last selected cooking zone will be maintained, and the
other cooking zone will be automatically reduced. The
display of this zone will flash first, then the level is au-
tomatically reduced to the highest appropriate position.
This limitation is set to 7400W from the factory, but it's
possible to change
Configuration procedure:
− Make sure there is no more pot on the hob
− Disconnect the appliance from the grid by removing
the fuse or turning the circuit breaker off.
− Reconnect the table to the grid
− Start the procedure within 2 minutes after reconnecting
the hob to the grid
− Make sure all cooking zones are off.
− Do not press on
.
1)
Press the
2)
Each display shows a .
3)
With one finger of the other hand press successively
and quickly (in less than 2s) on the . Starting from
the front right area and turning counter-clockwise
(1 -> 2 -> 3 -> 4) then release the
"beep" indicates an operating error. In this case,
repeat the operation from step 1.
4)
Select the [
5)
Use the slider to make [
"4". (This value in display "4" does not mean a
power limitation)
0
6)
Select the [
to enter the desired configuration in the display :
• 0 corresponds to 7400W - 2 fases
• 1 corresponds tot 6000W - 2 fases
• 2 corresponds to 5750W - 1 fase
• 3 corresponds to 4600W - 2 fases
• 4 corresponds to 3700W - 1 fase
• 5 corresponds to 3000W - 1 fase
• 6 corresponds to 2750W - 1 fase
• 7 corresponds to 2300W - 1 fase
• 8 corresponds to 1400W - 1 fase
7)
Press the
Never place container on the cooking zones
during setup.
15
key and hold it down.
key. A double
C/0
] key in display "4".
C/8
] appear in display
] key in display "5" and use the slider
key to confirm the configuration.
8