Download Print deze pagina

Novoferm tormatic NovoSwing Montage- En Bedieningshandleiding pagina 12

Advertenties

Operating instructions
Please read the operating instructions carefully
before starting the installation.
The gate should be installed by skilled technical
personnel.
If the installation is wrong, person can be in danger.
The supplier is not responsible for damage caused due
to improper installation.
Normal mode (0)
(Default mode)
The drive of the turning gate can be actuated by a pulse
transmitter such as a hand-held transmitter, key-
operated switch, etc. Short pulses are sufficient.
Functional sequence:
First pulse:
The drive starts and the gate moves to the set OPEN or
CLOSED end position.
Pulse received while the gate is moving:
Gate stops.
Next pulse:
Gate continues moving in the opposite direction.
Active wing control (only for normal mode)
With 2-wing doors, only one wing can be opened and
closed via the second channel of the hand-held
transmitter.
OPENC-CLOSE (1)
Functional sequence:
Pulse received when gate is closed:
The drive starts and the gate moves to the gate open
position.
Pulse received while the gate is moving up:
No effect on the gate
Pulse received while the gate is in up position:
Gate is moving up.
Pulse received while the gate is closing:
Gate stops and then moves open.
Automatic closing (2)
Any pulse causes the gate to open.
The gate closes automatically at the end of the hold-
open time and the advance warning time.
Automatic closing (3)
Any pulse causes the gate to close.
The gate closes automatically at the end of the hold-
open time and the advance warning time.
When the light barrier is interrupted, the hold-open time
is stopped and the advance warning time starts.
Automatic closing (4)
Any pulse causes the gate to open.
The gate closes automatically at the end of the hold-
open time and the advance warning time.
When another pulse is received, the hold-open time is
stopped and the advance warning time starts.
All manuals and user guides at all-guides.com
Automatic closing with the start-stop function (5)
Any pulse causes the gate to open.
When the gate reaches open position, automatic closing
can be interrupted by a pulse sent within 3 seconds.
The figure „6" is shown in the display. The next pulse
reactivates the automatic closing function.
Guard functions
Internal force limitation
If the gate hits an obstacle while closing, the drive stops
and moves away from the obstacle in the opposite
direction.
During soft run mode when the gate is closing, it opens
again a little to release the obstacle.
If the gate hits an obstacle while closing, the drive stops
and reverses the movement for about one second.
Light barrier stop B
If a light barrier is installed and that light barrier is
interrupted while the gate is closing, the gate stops and
moves in the opposite direction. Interruption of the light
barrier while the gate is opening has no effect.
Light barrier stop A
If a light barrier is installed and that light barrier is
interrupted while the gate is moving, the gate stops.
Unlocking the drive
(only when mains supply is switched off)
The gate can be unlocked and moved
manually in setting mode, during power
failure or other trouble. Release the wheel
on the underside with the triangular wrench
and fold it down. The gate can now be
opened and closed manually.
Gate stops
A stop should be set for the reference move of the gate
to open position. The stop should be set at least 5 mm
behind the normal door open position.
Preferably, the internal stop should be used.
The mechanical stop is approached once during teach-
in and serves as reference point.
In normal operation, the gate stops at the taught position.