6.2.1.2 Signals descriptions and on-screen displays

The led indicates if the timer ( Automatic program) is in the On phase (ON)
or the Off phase (OFF)
When lit, indicates that the unit is working in manual cooling mode.
When lit, indicates that the unit is working in automatic cooling mode.
When lit, indicates that the unit is working in manual ventilation mode.
When lit, indicates that the unit is working in automatic ventilation mode.
day 1-7
When lit, indicates the day-of–the-week is shown: 1°= Monday ...
Blinks during modifying values or parameters.
OFF
Unit off. Attention: the panel is always powered-on.
FAN
Ventilation mode only.
STARTING COOLING - Waits for the drain valve to close and turns the
P-00
water pump on.
P-01
COOLING
P-02
DRAIN
Cln
SELF CLEANING
STOP
End of program - OFF period
Loc
Control unit locked
--:--
Free space in memory
- -
Temperature and humidity probe disconnected
Communication doesn't work properly. It's possible a wrong connection of
En
the wires
EE
Eeprom failure, try to turn off and turn on the unit
TIME OUT filling or draining tank failure. To cancel the event, try to power
EA
off and to power on again. If failure is still on display, it is necessary to do
maintenance the unit.
Clock error. The time on the remote controller is not set. The device sets
Etc
automatically the time to 8.10 am on Monday. Until the time is not set, the
display will show the same message. Set the current time.
6.2.2 Switching ON
Keep
key pressed until the display will shows the time
6.2.3 Switching OFF
To stop the unit functioning, keep
14
key pressed until the display will show OFF