INSTALLATION
Burner of SOMIPRESS type (according to the "Somipress" symbol on burner compo-
nents)
Type of gas
G20 2E 20 mbar
G30 3B/P 50mbar
Exchange of a burner noz-
zle – unscrew the nozzle
with special socket span-
ner No 7 and replace with
a new one according to a
type of gas (see tables).
The procedure for changing the gas type
Flame
Burner
full flame
hob
small flame
full flame
oven
small flame
auxiliary
gas injector
diameter
gas injector diameter [mm]
[mm]
nominal
nominal
thermal
thermal
power
power
1,00 kW
1,40 kW
0,72
0,85
0,45
0,48
Conversion from LPG
to natural gas
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and check the
flame size.
1.Replace burner nozzle with
the appropriate nozzle accor-
ding to the table.
2.Gently tighten the adjusting
screw and adjust the flame.
The temperature in the oven
should be 150
Burner
medium
gas injector diameter [mm]
nominal
nominal
thermal
thermal
power
power
1,80 kW
2,40 kW
0,98
0,58
In order to perform adjusting operations, take
off the knobs. Adjusting elements of the oven
burner are accessible after drawing out the
oven chamber floor.
Conversion from natural
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and check the
flame size.
1.Replace burner nozzle
with the appropriate nozzle
according to the table.
2.Gently tighten the adju-
sting screw and adjust the
flame. The temperature in
C.
the oven should be 150
O
O
16
large
nominal
thermal
power
2,80 kW
1,07
1,17
0,69
0,75
gas to LPG
C.
oven
gas injector
diameter
[mm]
nominal
thermal
power
2,80 kW
1,30