Autotest mode
1.
Connect one end of a cable to the master unit and
connect the other end to the remote unit
2.
Select 'Autotest' function at the bottom of the
EazyLAN
3.
Push the testbutton, the EazyLAN will automatically
check all pins
4.
When all pins are checked, the EazyLAN will indicate
a PASS or FAIL:
When the cable is correct:
- the green 'Pass' LED illuminates
- all pin LEDs illuminate
- the EazyLAN will beep 3x
When the cable fails:
- the red 'Fail' LED illuminates
- the failed pin LED(s) will not illuminate
- the cause is indicated by the Open, Short or
Cross LED
- the EazyLAN will beep:
Open
Short
Cross
Step mode
1.
Connect one end of a cable to the master unit and
connect the other end to the remote unit
2.
Select 'Step' function at the bottom of the EazyLAN
3.
Push the testbutton, the EazyLAN will check the first
pin, press the testbutton again several times to check
all other pins
4.
When all pins are checked, the EazyLAN will indicate
a PASS or FAIL (see no. 4 above)
1x
4x
2x
www.nieaf-smitt.com
Nieaf-Smitt is a brand name of Mors Smitt
13