WHO guidance states that to protect non-smoking, middle-aged, and elderly population groups with documented or
latent coronary artery disease from acute ischemic heart attacks, and to protect the foetuses of non-smoking
pregnant women from untoward hypoxic effects, a COHb level of 2.5% should not be exceeded. The following WHO
guideline values and periods of time-weighted average exposures have been determined in such a way that the COHb
level of 2.5% is not exceeded, even when a normal subject engages in light or moderate exercise:
100 mg/m³ (90 ppm) for 15 min.
60 mg/m³ (50 ppm) for 30 min.
30 mg/m³ (25 ppm) for 1 h.
10 mg/m³ (10 ppm) for 8 h.
7.3
Normal COHb levels
Under normal conditions, humans typically have low levels of COHb of between 0.3% and 0.7% present within the
body. These levels are considered neither beneficial nor harmful.
7.4
Tobacco smoking
Tobacco smokers are exposed to significant concentrations of CO. In cigarette smokers, the COHb concentration
varies between 5%-9%, while heavy cigar smokers may exceed 10%.
WARNING! Exposure to high levels of carbon monoxide can be fatal or cause permanent damage and disabilities.
WARNING! The device may not prevent the chronic effects of carbon monoxide exposure, and that the device will
not fully safeguard individuals at special risk.
8.
SERVICE AND CONTACT
Would you like to contact us? That is possible! To ensure that we can serve our customers as well and quickly as
possible, we kindly ask you to take the following into account:
For questions about the installation, use or operation of this product:
Go to
www.lifeboxsecurity.fr
frequently asked questions, detailed installation videos and the most recent version of the manual for your
product.
Cannot find a solution on the website? Then leave a question via the product page. We will help you as soon as
possible.
9.
SPECIFICATIONS
Model
Product standards
Type of apparatus
Power Supply
Recommend battery type
Sensor Type
Product life
Standby Current
Alarm Current
Operation Ambient Condition
Storage/Transport Ambient Condition
Alarm sound
Low Battery warning silence
Installation Location
Detection range
Size
Weight
to quickly get an answer to your question. Here you will find answers to
: DETCO280NF
: EN 50291-1:2018
: Type B
: 3V (2pcs AA alkaline battery)
: Caution - the correct operation of the detector is ensured by the
use of one of the following batteries: GP GN15A or ENERGIZER E91
(The normal service life is 3years)
: Electrochemical
: 10 years after activation
: <20μA (average)
: <50mA (average)
: -10 ~ +45°C, 25 ~ 95%RH
: -20 ~ +50°C, 10 ~95%RH
: ≥85DB at 3m
: about 9 hours
: Wall
: Max. 40 m2 within a room.
: 120 x 80 x 37 ± 1mm
: 102 ± 5g (net)
- 8 -