Deactivate ring tone/melody (e.g. during the night)
The ring tone/melody can be deactivated, e.g. in order to prevent
disturbance during the night. Either press the mute button on the
indoor unit once briefly. The LED below the mute button lights up red
as a reminder that the melody is deactivated. To activate the melody
again press the mute button again briefly. When the red LED goes out
the melody has been re-activated.
The optical signal (surround light on the talk and door opener button)
remains active, even then the ring tone/melody is deactivated and still
rings. The red LED flashes if the bell is rung while the mute is activated.
NOTE: If the VTX-BELL module is used then this will also be deactivated
in the silent mode, i.e. the connected receivers will not give a
signal either.
IMPORTANT: The indoor station needs to be activated for the
following settings (e.g. by pressing the talk button). Otherwise it is not
possible to set the talk/volume, and melody.
Speaking volume
The two side buttons (B. 12 and 13) can be used to set the speaking
volume in several steps. Button 12 is used to increase the volume and
button 13 to reduce it.
Melody selection
The next melody is played every time you press the
(B/C.11). The last melody to be played is automatically stored.
OPERATION (as door intercom system)
1. Press the bell button.
2. The stored ring tone will play on the corresponding indoor
station(s)
3. Accept the conversation on the indoor unit by pressing briefly on
the talk button ( ).
4. If a door opener is connection then you can activate it by briefly
pressing the door opener button ( ). The bell button will light
green for the duration of the door opener as confirmation.
5. Press the talk button ( ) briefly in order to switch the system
back to standby operation.
Note: If a floor button is connected then an unchangeable ring tone
is played when the floor button is activated. This ring tone is fixed
and is not included in the 'normal' tones/melodies to make it easy to
differentiate.
OPERATION (as internal house intercom)
All indoor units that are connected to the same bell button can also be
used as an internal intercom.
1. Press the internal button
2. To accept the conversation on one of the other connected indoor
3. The talk button needs to be pressed briefly on one of the two
Note: It is not possible to set different ring tones for internal and
external calls.
Technical data:
Outdoor station
Operating voltage: 15V DC
Standby power: <0.5W
Connection for door opener: ~ 12V DC, max. 0.9 A
Bell button illumination: automatic via CDS sensor
Indoor station
button
Operating voltage: 15V DC
Standby power: <0.5W
NOTES
The functionality of the unit can be affected by the influence of strong
static, electrical or high frequency fields (discharging, mobile phones,
radios, microwaves).
Cleaning and maintenance
Always disconnect mains powered units from the mains supply before
cleaning (disconnect the plug). The unit housing can be cleaned using
a soapy soft cloth. Do not use any abrasive materials or chemicals.
Remove dust build-up from ventilation slits using a brush and clean up
using a vacuum cleaner. Do not hold the vacuum cleaner nozzle directly
against the unit.
SAFETY INSTRUCTION
In the event of damage to the housing, connectors, power cables or
isolation shielding, switch off the device immediately and disconnect
17 17
(B. 7) on the indoor station from
which you wish to reach another indoor station. All the connected
indoor station will ring. No image will be shown.
stations you need to briefly press the talk button there (B. 6).
indoor stations in order to end the conversation.
ENGLISH | VISTUS-AD
GB