The cooler uses CO2 refrigerant that operates at high pressures. A high pressures safety switch is used to
protect the system from exceeding the desired safety limit. When the pressure switch activates it cuts off the
power supply to the controller, which in turn shuts the complete cooler down. After the system pressures
comes back to the normal range, the pressure safety switch is deactivated and the cooler starts to operate
normal again.
If the supply cord is connected to the plug and the cooler does not operate (lamps are off, all electrical
components are off), please unplug the cooler and call a qualified service technician who has experience with
CO2 refrigerators and is authorized to work with CO2 refrigerators. Please do not try to repair the cooler by
yourself.
3. TECHNICAL FEATURES
1. Door
2. Power compartment
3. Shelf
4. Adjustable height
5. Interior ventilation fan
6. Canopy
7. Green light
8. Thermostat setting knob
9. Lighting switch
10. Fan switch
11. Interior lighting
12. Thermometer
13. Electronic thermostat (optional)
www.combisteel.com
5