What To Do If The Descaling Process Is Interrupted - Gaggia Milano Magenta Plus Gebruiksaanwijzing

Inhoudsopgave

Advertenties

Beschikbare talen

Beschikbare talen

24
English
4219-465-02411 MAN. GAG. MAGENTA Plus EN-NL-PL Rev 03.indd 24
Pour the entire bottle of Gaggia descaling solution into the water tank and fill
5
the tank with water up to the CALC CLEAN level. Reinsert it into the machine.
Place a large recipient (1.5l) under the steam tube and the coffee dispensing
6
spout.
7
Follow the instructions shown on the display to launch the descaling
procedure. This procedure lasts approximately 25 minutes and consists of
a descaling cycle and a rinse cycle, carried out with dispensing at regular
intervals.
Once the descaling cycle is complete, rinse the water circuit and tank by
8
following the instructions shown on the display.
Position the INTENZA+ filter back into the water tank.
9
Note: it is possible to pause and resume the procedure at any time by pressing the
START/STOP
button.
Warning: when the descaling procedure is active, the brew group cannot be
removed. Wait for the descaling process to end, then remove the brew group.

What to do if the descaling process is interrupted

You can exit the descaling procedure by keeping the ON/OFF
control panel, pressed for a few seconds. If the descaling procedure is interrupted
before its completion, proceed as follows:
1
Empty the water tank and wash it thoroughly.
Fill the water tank with running water up to the CALC CLEAN level mark, then
2
switch the machine back on. The machine will warm up and perform an
automatic rinse cycle.
Before preparing any beverages, carry out a manual rinse cycle as described in
3
the dedicated chapter.
Note: if the procedure has not been completed, it will be necessary to carry out
another descaling procedure as soon as possible.