13. Logging data
The data logger is dust tight and jet water protected with attached protective cap (10) and rubber seals (8)
only. This protection allows permanent logging operation in damp rooms and outdoors.
Before using ensure that the protective cap is tightly attached to the data logger and the housing is com-
pletely closed.
Do not immerse into water!
Avoid operation near strong magnetic fields.
Do not cover the sensor openings.
• Ensure that rubber seals are in the correct positions and that the cap is tightly put on the data logger.
• Place the data logger at the intended location.
• The protective cap must be removed for inserting/changing battery or reading the saved data via a computer. Pull
the protective cap off the device.
• Attach the protective cap tightly to data logger before next recording.
a) Enter function menu
Press button DOWN (5) to enter the function menu. The latest recorded measurement, logger ID and selected start/
stop mode during configuration appear in sequence by consecutive presses of the button DOWN (5).
b) Start recording
• Recording starts based on configuration setting "RECORD START CONDITION".
• When the data logger starts recording, "
• "P" indicates data logger is ready for recording and it disappears once the data logger records.
c) Stop recording
• Recording stops based on the configuration setting "STOP STYLE". When the "NONE" stop style was selected,
then the recording stops based on the setting "RECORD START CONDITION".
• When the data logger stops recording, "
d) Show remaining time until start/end of recording
• Press button DOWN (5) to enter the function menu.
• Press button DOWN (5) consecutive until "TIME START" and/or "TIME STOP" and remaining time (in hours/min-
utes or days) are shown in LC-display.
• Time duration below 24 hours is in HH:MM format. If the remaining time exceeds 24 hours, it is shown as days " ".
• Once the recording starts/stops, the latest measurement is shown in the display.
• Press button DOWN (5) to return to function menu.
" appears on the LC display.
" appears on the LC display.