Download Print deze pagina

VOLTCRAFT VC-11015505 Gebruiksaanwijzing pagina 37

Advertenties

Beschikbare talen

Beschikbare talen

9. Initial operation
a) Protective cap
The data logger is only dust tight and jet water protected with attached protective cap (10) and rubber seals
(8). This protection allows permanent logging operation in damp rooms and outdoors.
• Only remove the protective cap for replacing the battery or reading the data on the computer.
• Remove the protective cap by pulling it off from the data logger. The protective cap fits tightly due to the rubber
seal (8).
• Place the protective cap tightly back onto the data logger.
b) Connect to the computer
• Remove the protective cap (10) from the data logger.
• Connect the data logger to an available USB port of your computer.
• The computer recognizes the new hardware. The model type of your data logger appears as a mass storage device
on your computer.
c) Disconnect from the computer
• Eject the data logger from your computer and remove it.
• Place the protective cap back on the data logger.
d) Choose start/stop mode
• Choose start mode from "RECORD START CONDITION" during configuration.
• Choose stop mode from "STOP STYLE" during configuration.
e) Define date and time during configuration
• Select month, year and time with date picker and time sliders. The time will be shown as "TIME" in HH:MM:SS
format. Confirm with "DONE". Date and time settings are displayed in the corresponding fields.
• Alternatively, click "NOW", if you require an immediate start of logging. Actual date and time - as per locally set on
your computer - will be filled automatically into field "START TIME"/"STOP TIME".
f) Button ENTER
• Press button ENTER (7) to switch between maximum and minimum reading.
• Press and hold button ENTER (7) for few seconds to start/stop logging or activate/deactivate pause function.