INSTALLATION
1 400/230V two phase connection
with a neutral lead, terminals
2-3 are bridged, neutral lead to
terminal 4, and the protective
conductor to
2 For a 400/230 V three phase
connection with a neutral lead
connected to terminal 4, and the
protective conductor to
L1=R, L2=S, L3=T, N=neutral lead connection,
WIRING DIAGRAM
Important! Heating elements operate at 400/230V.
Important! For each connection
the protective conductor must
be connected to the terminal
marked
2N~
1
L1
L2
PE
3N~
1
L1
L2
PE
=protective lead terminal
16
Recommended
connection lead
H05VV-F4G2,5
3
2
4X2,5mm
4
N
H05VV-F5G1,5
2
3
5X1,5mm
L3
4
N
2
2