TERMINAL STRIP CONNECTIONS:
Earth
N
Neutral
L
Live input of controller
L
Live input for 3-way mixing valve (warm water supply of water heater)
1
L
Live input for 3-way mixing valve (return water of plate heat exchanger)
2
L
Live input for heating pump
5
L
Live input for DHW pump
6
L
Live output of Switched Live room thermostat
7
COMPONENTENS:
AA
Controller of dual service system (HM 3.0)
BB
3-way mixing valve (230 V
CC
Heating pump (230 V
DD
DHW pump (230 V
EE
Temperature sensor (S
FF
Room thermostat (24 V
GG
Room thermostat (230 V
HH
Communication between the water heater controller and the solar heating
system controller
K
Double-pole isolator
CONTROLLER CONNECTIONS:
J3
Connection of room thermostat (ON/OFF)
J13
Connection of temperature sensor S
J16
Connection of BUS-link communication
F2
Fuse (T 3,15 A - 250 V)
)
AC
, 0,8A)
AC
)
AC
- heating system) (12 kΩ NTC)
5
- ON/OFF)
AC
- Switched Live)
AC
(1-3)
5