FGV150 --- /FGV160 --- /FGV360 ---
G30 28-30mbar 7.5 kW 545 g/h
II2EK3B/P NL Class: 1
RAPID BURNER
Injector diam (1/100 mm)
Nominal Rating (kw)
Consumption in 1h
SEMI-RAPID BURNER
Injector diam (1/100 mm)
Nominal Rating (kw)
Consumption in 1h
AUXILIARY BURNER
Injector diam (1/100 mm)
Nominal Rating (kw)
Consumption in 1h
FGV460 ---
G30 28-30mbar 8.3 kW 604 g/h
II2EK3B/P NL Class: 1
WOK BURNER
Injector diam (1/100 mm)
Nominal Rating (kw)
Consumption in 1h
SEMI-RAPID BURNER
Injector diam (1/100 mm)
Nominal Rating (kw)
Consumption in 1h
AUXILIARY BURNER
Injector diam (1/100 mm)
Nominal Rating (kw)
Consumption in 1h
NG/G20/G25.3
20/25 mbar
125
125
3
3
325.0 l/h
285.6
l/h
94
94
1.75
1.75
189.6 l/h
166.7 l/h
72
72
1
1
108.3 l/h
95.2 l/h
NG/G20/G25.3
20/25 mbar
148
148
3.8
3.8
411.7 l/h
361.9 l/h
94
94
1.75
1.75
189.6 l/h
166.7 l/h
72
72
1
1
108.3 l/h
95.2 l/h
LPG/G30
28-30 mbar
85
3
218.1 g/h
65
1.75
127.2 g/h
50
1
72.7 g/h
LPG/G30
28-30 mbar
98
3.8
276.3 g/h
65
1.75
127.2 g/h
50
1
72.7 g/h