Preparation
The chimney flue
Please observe the following before fitting the stove:
Before connecting the stove to an existing chimney, it must first be professionally.
cleaned and checked by a qualified chimney sweep.
Any shut-off valves should be removed.
The flue pipe of the stove should be directly connected to the chimney flue.
The negative pressure in the flue must be at least 12 Pa or 0.12 mbar.
The flue must always terminate in outlet area 1. See drawing.
3
A X
X > 23˚
The chimney flue should be clean, leak-proof and unobstructed at the time of installation
and have a diameter of at least 150 mm.
Any bends in the flue must not exceed 45 degrees.
Ensure that the chimney flue can dispose of any flue gases sufficiently, properly and safely.
The values to calculate the flue can be found under Technical data
1
3
1
500 mm
X < 23˚
Page 27.