Preparation
The chimney flue
Please observe the following before fitting the stove:
•
Before connecting the stove to an existing chimney, it must first be professionally.
•
cleaned and checked by a qualified chimney sweep.
•
Any shut-off valves should be removed.
•
The flue pipe of the stove should be directly connected to the chimney flue.
•
The negative pressure in the flue must be at least 12 Pa or 0.12 mbar.
•
The flue must always terminate in outlet area 1. See drawing.
3
A X
X > 23˚
•
The chimney flue should be clean, leak-proof and unobstructed at the time of installation
and have a diameter of at least 150 mm.
•
Any bends in the flue must not exceed 45 degrees.
•
Ensure that the chimney flue can dispose of any flue gases sufficiently, properly and safely.
•
The values to calculate the flue can be found under Technical data
1
3
1
500 mm
X < 23˚
Page 27.