CONVEYOR
KEYLOCK SWITCH
13
21
1000594
CONTACT BLOCK
1000595
14
22
TRIGGER DISTRIBUTION HARNESS
TO GUN MODULES
(SEE SHEETS 2-9)
TO AXIS CTRLR
(REFER TO AXIS
CNTRLR MANUAL)
WHITE "A"
T1
J2
WHITE "B"
T2
WHITE "C"
T3
WHITE "D"
T4
WHITE "E"
T5
WHITE "F"
T6
WHITE "G"
J6
T7
WHITE "H"
T8
RED
LO-1
RED
LO-2
RED
LO-3
RED
LO-4
RED
ENCORE LT
LO-5
TRIGGER DISTRIBUTION
BLUE
CON-1
PCA
BLUE
CON-2
BLUE
CON-3
BLUE
CON-4
BLUE
J5
CON-5
BLACK
COM
BLACK
COM
BLACK
COM
BLACK
COM
BLACK
J4
COM
POWER/TRIGGER DISTRIBUTION
Afb. 7‐3
Multi‐Gun Controller Wiring Diagram (1 of 3)
E 2012 Nordson Corporation
TRIGGER ALL
24
14
2 POSITION SWITCH
334806
CONTACT BLOCK
288806
23
13
BYPASS/LOCKOUT
HARNESS
SWITCHED POWER
L1, L2, GND
JUMPERED
GND
GND
GND
GND
J1
CGRND
L1
L1
L1
L1
ORANGE
240V
J3
120V
L2
L2
L2
L2
RED
AC COM
L2
L2
L2
L2
L1
L1
L1
L1
GND
GND
GND
GND
D
C
SWITCHED POWER
DISTRIBUTION HARNESS
UNSWITCHED
TO GUN
MODULES
POWER
(SEE SHEETS
TO AXIS CTRLR
2, 4, 6, 8)
POWER ON/OFF
24
14
2 POSITION SWITCH
334806
CONTACT BLOCK
288806
23
13
SWITCH TO T.B.
POWER HARNESS
GND
GND
TERMINAL BLOCK
ASSEMBLY
L1
L1
L2
L2
POWER JUMPER
L2 L1
GROUP
L2
L2
L1
L1
GND
GND
BLUE
BLUE
4
2
10A
B
A
FILTER
5
334805
BROWN
BROWN
3
1
GRN/YEL
GRN/YEL
ORANGE
RED
GND
(CABINET)
BLUE
BROWN
GRN/YEL
INPUT: 100-250VAC
50-60Hz, 1 PHASE
6.3A, 370VA MAX
POWER HARNESS/CONDUIT
Encore LT Automatic Controller Wiring Diagrams
REAR COVER
WHITE
WHITE
4
2
3A
FILTER
5
1107696
BLACK
BLACK
3
1
1
7‐5
GROUND WIRE ASSY.
(GREEN/YELLOW)
CABINET
GND
GND
GAGE
GAGE GROUND ASSY
BASE GND
60
40
4
3
2
5
6
0
7
BAR
100 x kPa
psi
P/N 7179309_02