Functies voor programmering, besturing en uitlezing via de bus (PROFIBUS) of via een PC
Bereik/aantal
Functie
Language
Local/remote control
Local reference
Active Setup
Programming Setup
Copying of Setups
LCP copy
Display scaling of motor frequency 1
Display line 2
Display line 1.1
Display line 1.2
Display line 1.3
Local control/configaration
Local stop
Local jog
Local reversing
Local reset of trip
Lock for data change
Operating state at power up, local..3
Configuration
Torque characteristics
Motor power
Motor voltage
Motor frequency
Motor current
Rated motor speed
DC braking time
DC brake cut-in frequency
Motor thermal protection
DC braking voltage
Start voltage
Start compensation
U/f ratio
Slip compensation
DC holding voltage
Brake cut out frequency
Brake cut in frequency
Rotation direction
Min. output frequency (f
Max. output frequency (f
Reference/feedback range
Minimum reference
Maximum reference
Ramp-up time 1
Ramp-down time 1
Jog ramp time
Quick stop ramp-down time
Jog frequency
Reference function
100
instellingen/waarde
6
2
4
4
4
4
24
5
2
2
2
2
2
2
4
XX.XX kW - dep. on unit
XX.XX V - dep. on unit
XX.X Hz - dep. on unit
XX.XX A - dep. on unit
XX rpm - dep. on unit
0.0 (off) - 60.0 sec.
0.0 Hz - f
MAX
2
0-100 %
0.00 - 100.00 V
0.0 - 300.0 %
0.00 - 20.00 V/Hz
-500.0 - +500.0 %
0 - 100 %
0.5 - 132 Hz
0.5 - 132 Hz
3
)
0.0 Hz - f
MIN
MAX
)
f
f
MAX
MIN -
RANGE
Min. - max./-max.- +max. Min. - Max.
-100,000.000 - Ref
Ref
- 100,000.000
MIN
0.15 - 3600.00 sec.
0.15 - 3600.00 sec.
0.15 - 3600.00 sec.
0.15 - 3600.00 sec.
0 Hz - f
MAX
2
FCM Serie 300
Beschreven in de
Fabrieksinstelling
English
Remote control
000.000
Setup 1
Active Setup
No copying
No copying
100
Frequency [Hz]
Reference [%]
Motor current [A]
Power [kW]
LCP digital control
Possible
Not possible
Not possible
Possible
Not locked
Forced stop, use saved ref. Parameter 019
Speed regulation open loop Parameter 100
Constant torque
10.0 sec.
0.0 Hz
Disable
0.0 %
Motor dependent
100.0 %
Motor dependent
100.0 %
0 %
3.0 Hz
3.0 Hz
Only clockwise 0 - 132 Hz Parameter 200
0.0 Hz
f
(132 Hz)
RANGE
0.000
MAX
50.000
3.00 sec.
3.00 sec.
3.00 sec.
3.00 sec.
10.0 Hz
Sum
MG.03.B6.10 - VLT is een geregistreerd handelsmerk van Danfoss
Par. no.
Parameter 001
Parameter 002
Parameter 003
Parameter 004
Parameter 005
Parameter 006
Parameter 007
Parameter 008
Parameter 009
Parameter 010
Parameter 011
Parameter 012
Parameter 013
Parameter 014
Parameter 015
Parameter 016
Parameter 017
Parameter 018
Parameter 101
Parameter 102
Parameter 103
Parameter 104
Parameter 105
Parameter 106
Parameter 126
Parameter 127
Parameter 128
Parameter 132
Parameter 133
Parameter 134
Parameter 135
Parameter 136
Parameter 137
Parameter 138
Parameter 139
Parameter 201
Parameter 202
Parameter 203
Parameter 204
Parameter 205
Parameter 207
Parameter 208
Parameter 211
Parameter 212
Parameter 213
Parameter 214