4.10 Installing inside an open fi replace
The Jøtul I 520 is designed to be placed inside a pre-existing, code-compliant masonry fi replace. The fi replace must satisfy the
requirements regarding installation against combustible materials. It is important that the convection air openings are suffi ciently
large (500 / 750 cm 2 ) to utilize the heat emission from the product.
There are several options for installation in hearths/open fi replaces. Here are three options:
1) Placed in a corner with plenty of space
The illustration shows the Jøtul I 520 FR (glass in the door and on the right-hand side). In this example, a sheet metal grid is used
(optional - item no. 50045748) to fi ll the space between the insert and the fi replace.
Fig. 27
A
A
The sheet metal grid (A) must be cut to fi t the fi replace. See separate manual for instructions on how to fi t the sheet metal grids.
20