Download Inhoudsopgave Inhoud Print deze pagina

Appendix A - Serial Printers - Radiodetection RD6000DSL Handleiding

Inhoudsopgave

Advertenties

Maximum Range (live):
19,400.0m at 99.0% VOP
11,700.0m at 60.0% VOP
Range varies with VOP, Maximum
testable cable length varies with pulse width
and cable type
Maximum Range (stored):
3,600.0m at 99.0% VOP
2,200.0m at 60.0% VOP
Range varies with VOP, pulse width and
cable type
Input Protection:
400V from DC to 60Hz
Velocity of Propagation:
Unloaded Cable Range:
VOP(%) ranging from 30.0% to 99.0%
Loaded Cable Range:
Unloaded Cable Range:
V/2 ranging from 45.0 to 148.4 m/µs
Loaded Cable Range:
Super-Store Storage:
32 TDR waveform records with 6144
16-bit samples each
8 Auto - Test records
8 RFL Records
8 Power Spectral Density Records
8 Open/Cap Meter Records
Software Noise Filters:
4x, 8x, 16x, 32x, 64x, 128x, 50/60 Hz,
High-pass filter
Resistance Fault Locator (RFL)
Location Range:
Resistance Fault Range:
Accuracy (3-wire):
Accuracy (4-wire):
Accuracy (Kupfmuller):
Remote Device
Communications for:
Short Pair
Open Pair
Connect through to exchange
Send tones for Insertion Loss and Crosstalk tests
Set Terminations
Tone for pair identification
Compliance
Europe: Complies with 89/336/EEC and 73/23/EEC
USA:
Complies with Part 15 of the FCC Rules
Ingress Protection
IP54
Handleiding 6000DSL
VOP(%) ranging from 0.8% to 20.0%
V/2 ranging from 1.2 to 30.0 m/µs
0 to 45 km
0 to 20 M
+/- 0.25% of DTS plus +/- 0.4
+/- 0.25% of DTS plus +/- 0.25
+/- 1.0% of DTS plus +/- 1
65

Advertenties

Inhoudsopgave
loading

Inhoudsopgave