AC Voltmeter
Range:
0.0 to 400.0V
Resolution:
0.1V
Accuracy:
2% +/- 0.1V
1 M Ω
Impedance:
Foreign Battery
Range:
2.0 to 400.0V
Resolution:
0.1V
Accuracy:
1% +/- 0.1V
1 M Ω
Impedance:
Resistance
0.0 to 1999.9 Ω
Range:
Resolution:
0.1 Ω
0.2% +/- 0.2 Ω
Accuracy:
Range:
2,000 to 10,000 Ω
1 Ω
Resolution:
0.2% +/- 1 Ω
Accuracy:
IR (Insulation Resistance)
Voltages:
50V, 100V, 250V, 500V
0.00M Ω
Range:
0.01M Ω
Resolution:
Accuracy:
2% +/-0.01M Ω
10.0M Ω
Range:
Resolution:
0.1M Ω
Accuracy:
4%
Range:
100M Ω
1M Ω
Resolution:
Accuracy:
10%
Pair Quality (POTS)
Loop Current
Range:
0.0 to 120.0mA
Resolution:
0.1mA
Accuracy:
1% +/- 0.2mA
Load:
500 Ohms
Noise Metallic (Transverse Noise) - Continuous and Peak
Range:
0 to 50 dBrnC (-90 to -40 dBmp)
Resolution:
1 dB
Accuracy:
+/-2 dB
Filter:
User selectable P/C weighted or flat (3kHz)
Power Influence (Longitudinal Noise)
Range:
40 to 100 dBrnC (-50 to 100 dBmp)
Resolution:
1 dB
Handleiding 6000DSL
to 9.99M Ω
to 99.9M Ω
to 999M Ω