Fault Location:
Open/Capacitance Meter
Range:
0 to 99.9 m
Resolution:
0.1 m
Accuracy:
2% +/-1 m
Range:
100m to 999m
Resolution:
1m
Accuracy:
3%
Range:
100m to 999m
Resolution:
1m
Accuracy:
3%
Range:
1,000m to 9,990m
Resolution:
10 m
Accuracy:
5%
Range:
10,000m to 49,900m
Resolution:
100 m
Accuracy:
8%
Range:
0 nF to 9.99 nF
Resolution:
0.01 nF
Accuracy:
2% +/- 0.06 nF
Range:
10.0 nF to 99.9 nF
Resolution:
0.1 nF
Accuracy:
+/- 3%
Range:
100 nF to 999 nF
Resolution:
1 nF
Accuracy:
+/- 5%
Range:
1,000 nF to 2,000 nF
Resolution:
1 nF
Accuracy:
+/- 8%
Time Domain Reflectometer (PET)
Range:
0 to 610 m
Resolution:
< 0.07 m at 99% VOP, < 0.02 m at 30%
Range:
610 m and greater
Resolution:
0.1 m at any VOP
Distance Accuracy:
+/- 0.15 m plus +/- 0.01% of reading
Vertical Resolution:
14 bits with 137 dots displayed
Vertical Sensitivity:
Greater than 65 dB
Output Signal:
Pulse widths of 2ns, 25ns, 100ns, 500ns,
1µs, 4.4µs and 330µs
Output Balance:
Variable from 80
Handleiding 6000DSL
to 120
64