1
Idx
sIdx
Naam
01
command
02
status
03
response
FBF1
Exception Reset Command
01
command
02
status
03
response
FBF2
Store Parameters Command
01
command
02
status
03
response
FBF3
Calculate Checksum Command
01
command
02
status
03
response
1. Idx = index, sIdx = subindex, hexadecimaal
2. RO = alleen leesbaar, RW = lees- /schrijfbaar, P = geschikt voor procesgegevens
1
Idx
sIdx
Naam
4001
Cfg Pump Operation
21
Intf. Configuration
84
Nominal Speed
85
Process Gas
86
Cfg. Ready for Process
87
Speed Switchpoint 1
88
Speed Switchpoint 2
89
Enable Run-up Timer
8A
Run-up Time
4002
Cfg Pump Power/Temperature
11
Max. Power
4005
Cfg Component Operation
02
Htg. Setpoint
11
Vnt. Configuration
12
Vnt. Start Speed
13
Vnt. Stop Time
41
Bkp. Configuration
42
Bkp. Start Power
43
Bkp. Stop Power
55
Prs1.Correction factor
57
Prs1.Switchpoint
65
Prs2.Correction factor
67
Prs2.Switchpoint
Configuratiegegevens (regeling-> TC 1200 EC)
2
Type
Toegang
BYTE()
RW
USINT
RO
BYTE()
RO
BYTE()
RW
USINT
RO
BYTE()
RO
BYTE()
RW
USINT
RO
BYTE()
RO
BYTE()
RW
USINT
RO
BYTE()
RO
2
Type
Toegang
USINT
RW
UDINT
RW
USINT
RW P
USINT
RW P
USINT
RW P
USINT
RW P
BOOL
RW P
USINT
RW P
USINT
RW P
INT
RW P
USINT
RW P
USINT
RW P
UINT
RW P
USINT
RW P
UINT
RW P
UINT
RW P
REAL
RW P
REAL
RW P
REAL
RW P
REAL
RW P
Aansluiting "EtherCAT"
Beschrijving
Uitsluitend bij pomp uit en stil-
staand
{74h, 65h, 73h, 65h, 72h, ...
...0x00}: standard reset
...0x66}: factory reset
{74h, 65h, 73h, 65h, 72h}
R
: 81 00 00 00
H
W
: 01 00 00 00
H
Beschrijving
0: relais standard
1: omgekeerd
-1
min
0 = zware gassen
1 = lichte gassen
2: helium
0: Schakelpunt 1
1: Schakelpunt 1 en 2
% van het nominaal toerental
% van het nominaal toerental
min
%
°C
0: vertraagde beluchting
1: niet beluchten
2: direct beluchten
% van het nominaal toerental
s
0: Continubedrijf
1: Onderbroken bedrijf
2: vertraagde inschakeling
W
W
hPa
hPa
17