Download Print deze pagina

Parts And Options; The Swa 50Ii Can Be Equipped With The Following Sensors; The Standard Scope Of Supply For The Swa 50Ii Includes; General Functions - Becker SWA 50II Handleiding

Advertenties

Beschikbare talen

Beschikbare talen

SWA 50II cpl.
The SWA 50II can be equipped with the
following sensors:
AN2 wind speed sensor
LS10 light sensor
The standard scope of supply for the SWA 50II
includes:
1 SWA 50II control unit
1 AN2 wind speed sensor
1 LS10 light sensor
1 set fitting accessories for wind speed sensor
1 set fitting accessories for light sensor
1 2.2 kΩ resistor (for installation without wind sensor)
E
1 copy of installation instructions
N
G
L
I
S
H
Wind
If the wind speed is greater than the set wind threshold, the awning is retracted after expiry of the delay time
(3 sec.).
If the wind speed is less than the set wind threshold, the awning control is released again after expiry of the
inhibited movement time (15 min.).
Sun
If the sun intensity is greater than the set actuation threshold, the awning is extended after expiry of the
delay time (90 sec.).
If the sun intensity is less than the set actuation threshold, the awning is retracted after expiry of the delay
time (15 min.).
After expiry of the RUNNING TIME, the retracting and projecting movement in blind mode is automatically stopped
after 2 minutes, and in sunshade mode after 5 minutes. The power supply to the motor is then cut off.
The wind protection always takes priority, so that in the event of a wind alarm the awning is re-
tracted, extension is blocked simultaneously. During the wind alarm it is not possible to operate
the system.
16

Parts and Options

Item no. 4020 000 016 0
Item no. 3004 100 001 0
Item no. 4017 000 001 0

General Functions

Operating Instructions SWA 50II

Advertenties

loading