SCHEMI ELETTRICI - WIRING DIAGRAMS - SCHÉMAS ÉLECTRIQUES
SCHALTPLÄNE - ELEKTRISCHE SCHEMA'S
UNITÁ INTERNA/ INDOOR UNIT/ UNITE INTERNE/
RAUMGERÄT / INTERNE EENHEID
CCA 025 U-I
FUNCTION OF SWITCH
SWITCH FOR CCM UNIT ADDRESS
ON
ON
0
0
S2
+
S1
1 2
1 2
8
8
16~31
0~15
ADDRESS
Factory
Setting
ON
0
ON
0
S2
+
S1
8
1 2
8
1 2
48~63
32~47
ADDRESS
Factory
Setting
SWITCH
SW3
FOR AUTO-RESTART SETTING
ON
ON
ON
STATE
MODE
NO_REMEMBER
REMEMBER
Factory
Setting
SW6
SWITCH
FOR TEMP.COMPENSATION
ON
ON
ON
ON
ON
STATE
1 2
1 2
1 2
1 2
6
2
4
E function
VALUE
Factory
Setting
CCA 035 U-I
16022500004003 WIRING DIAGRAM
FUNCTION OF SWITCH
SWITCH FOR CCM UNIT ADDRESS
ON
ON
0
0
S2
+
S1
1 2
1 2
8
8
0~15
16~31
ADDRESS
Factory
Setting
ON
0
ON
0
S2
+
S1
8
1 2
8
1 2
48~63
32~47
ADDRESS
Factory
Setting
SW3
SWITCH
FOR AUTO-RESTART SETTING
ON
ON
ON
STATE
MODE
NO_REMEMBER
REMEMBER
Factory
Setting
SW6
SWITCH
FOR TEMP.COMPENSATION
ON
ON
ON
ON
ON
STATE
1 2
1 2
1 2
1 2
2
6
4
E function
VALUE
Factory
Setting
NOTA: COLLEGAMENTI A CURA DELL'INSTALLATORE / NOTE: WIRING TO BE DONE BY THE INSTALLER / REMARQUE : RACCOR-
DEMENTS À LA CHARGE DE L'INSTALLATEUR / HINWEIS: VOM INSTALLATEUR AUSZUFÜHRENDER ANSCHLUSS / OPMERKING:
AANSLUITINGEN UIT TE VOEREN DOOR DE INSTALLATEUR
ATTENZIONE! La posizione dei terminali potrebbe essere differente / WARNING! The actual shape of the components may be
different / ATTENTION ! La position des bornes pourrait être différente / ACHTUNG! Klemmenposition könnte abweichen / LET OP!
De positie van de eindstukken kan verschillen
142 /
Inner Driver
Anti-cold air
DC Motor
SW1
FAN MOTOR STOP-TEM
M
ON
24
1 2
Factory setting
ON
MAGNETIC
RING
15
Y/G
1 2
ON
8
3
M
1 2
According
ON
to the
Y/G
DRIVER MODLE
EEPROM
1 2
setting
Outer Driver DC Motor
FOR FAN MOTER CONTROL
SW2
SWITCH
THEN NO POWER REQUEST.
ON
ON
ON
STATE
MODE
FAN OFF
FAN ON
WATER LEVEL SWITCH
Factory
Setting
SW5
SWITCH
FOR MODE-PRIOR SETTING
ON
ON
ON
ON
ON
STATE
1 2
1 2
1 2
1 2
MODE
HEAT
COOL COOL
HEAT
Factory
Setting
Inner Driver
Anti-cold air
DC Motor
SW1
FAN MOTOR STOP-TEM
M
ON
24
1 2
Factory setting
ON
MAGNETIC
RING
15
1 2
ON
8
技术要求(版本号:D,2012-12)
3
M
1 2
According
ON
to the
DC MOTOR
Y/G
DRIVER MODLE
EEPROM
1 2
setting
Outer Driver DC Motor
FOR FAN MOTER CONTROL
SW2
SWITCH
THEN NO POWER REQUEST.
ON
ON
ON
STATE
technical requirement(Ver.: D, 2012-12)
MODE
FAN OFF
FAN ON
WATER LEVEL SWITCH
Factory
Setting
SW5
SWITCH
FOR MODE-PRIOR SETTING
Y/G
ON
ON
ON
ON
ON
STATE
1 2
1 2
1 2
1 2
COOL COOL
MODE
HEAT
HEAT
Factory
Setting
120±1mm
Alarm
TO WIRE
Output
CONTROLLER
5
TO WIRE
DISPLAY
CONTROLLER
BOARD
5
10
4
CN10A
CN40
ALARM
(CN10)
P5
CN15
DC MOTOR
CN33
INDOOR UNIT
M
2
MAINBOARD
CN13
PUMP
2
CN3
CN5
H
CH
CN4
E Y X
P2
P3
BROWN BLACK
Y/G
6
FAN1
To CCM
Comm.Bus
CAP1
120mm
Alarm
TO WIRE
Output
CONTROLLER
5
TO WIRE
DISPLAY
CONTROLLER
BOARD
5
10
4
CN10A
CN40
ALARM
(CN10)
P5
CN15
CN33
INDOOR UNIT
2
M
MAINBOARD
CN13
PUMP
2
CN3
CN5
H
CH
CN4
E Y X
P2
P3
BROWN BLACK
6
FAN1
To CCM
Comm.Bus
CAP1
NOTE:
The wiring diagram
NEWFAN
is for explanation
Remote
purpose only. The
M
Control
actual shape of the
components may be
different.
JR6
ON - OFF
RED
CN8
CN23
CN16
JR6
CN7
P4
4
CN6
BLACK
P1
CN1
CN110
CN14
WHITE
XS9
Y/G
POWER
MAGNETIC RING
TO OUTDOOR UNIT
NOTE:
The wiring diagram
NEWFAN
is for explanation
Remote
purpose only. The
M
Control
actual shape of the
components may be
different.
Reactor
JR6
ON - OFF
RED
CN8
CN23
CN16
JR6
P4
4
CN6
P1
CN1
CN110
CN14
XS9
RED
Y/G
1(L)
2(N)
W
S
NOTE:
MAGNETIC RING
Please don't connect "W" if there
is no "W" terminal in outdoor unit.
TO OUTDOOR UNIT
Reactor
RED
T2B
OUTER PIPE TEMP.
T2
T1
ROOM TEMP.
XP9
SWING
MOTOR
RED
T2
T1
ROOM TEMP.
XP9
SWING
MOTOR