10
BATTERIES
Insert 2 AAA batteries before use:
1. Remove the battery cover on the
back.
2. Insert batteries correctly so that the
markings correspond.
3. Refit the battery cover.
Important Notes
Low battery power will cause the
device to lose its effectiveness. Please
change to new batteries whenever
stimulation weakens. Alkaline batteries
are recommended as a stable power
source.
If the indicator lights fade, or if the
stimulation feels weak on your skin,
this may be an indication of low battery
power.
WARNING!
Replace only with the same or equiva-
lent type of batteries, as recommended
by the manufacturer:
2 x AAA (1.5 V) alkaline batteries.
Do not dispose of the batteries with
normal household waste, but hand
them in at an official collection point in
accordance with local regulations go-
verning the disposal of such materials.
Remove the batteries to prevent them
from running down whenever you are
planning to store the device for more
than 3 months.
If the device is used once a day for
about 30 minutes per treatment, one
pair of AAA Alkaline batteries should
last 3 to 6 months.
We recommend the use of Alkaline
batteries because they provide a
steady power level until it runs out.
Non-Alkaline and rechargeable batte-
ries have a tendency to decrease in
power level over time, and you might
mistakenly think the device is not wor-
king right because the treatment is not
as strong.
Please refer to the
Quick Guide for
pad placement
and user
instructions.
ELECTRODE PAD GUIDELINES
• Only use the original electrode
pads, gel and wires supplied by
the manufacturer because other
electrode pads and wires may not
be electrically compatible with your
device.
• The pads should only be used on
one person to avoid skin reactions
or cross-contamination.
• Always turn the device off before
removing or repositioning the elec-
trodes.
• Wash skin thoroughly and then dry
it before applying the electrodes.
• Apply the whole surface of the elec-
trode pads firmly to the skin.
• Do not use electrode pads that do
not stick properly to the skin, or
only partially stick to the skin.
CLEANING & MAINTENANCE
DR-HO'S Neck Pain Pro and Pain
Therapy device:
• Use a wet cloth or neutral cleanser
to wipe the surface.
• Do not use volatile liquids such as
alcohol, thinner or gasoline.
• Keep well away from moisture, high
temperatures, direct sunlight or
water droplets.
• Please do not disassemble, repair
or rebuild the device yourself
because this will invalidate the
warranty.
• Remove the batteries from the
device if it is not used for more than
3 months.
• If the skin looks red after treatment,
you should not treat that area until
the redness has disappeared.
• The electrode pads can be reused
30 to 50 times depending on your
skin type and other conditions.
Whenever you notice that the pads
are not sticking properly to your
skin, or if the gel pads feel dry, you
should dab the gels with a small
amount of water by hand or using
the spray bottle (do not wash them
with water directly). This will help
restore the adhesiveness and
conductivity of the electrode pads.
If moistening the pads fails to make
them sticky again, they may need to
be replaced.
Body and foot pads:
• Never stick two electrode pads
close to each other.
• Keep the electrode pads clean
and never expose them to high
temperature and direct sunshine.
• Keep the electrode pads at
temperatures of 5~40°C.
• Gently clean the electrode pads
with a moist cloth or use a brush to
remove dust.
• Do not clean the pads with hot
water or chemicals.
• Do not touch the gel of the pads
with your fingers, as this could
reduce their adhesiveness.
11