4.3
Lengten rookgasafvoerbuis
4.3.1
Toegestane lengten rookgasafvoerbuis
De maximaal toegestane lengten van de rookgasafvoerbuizen zijn opge-
nomen in tabel 10.
Rookgasafvoer con-
Afbeel-
form CEN
dingen
Schacht
B
7
23P
B
8
33
C
9
33
C
10
53
C
11
93
Horizontaal
C
12
13
13
Condens 2300i W – 6720891989 (2018/11)
Diameter van de
Toestel
rookgastoebehoren
80 mm star
GC2300iW 19/30 C 23
GC2300iW 19/30 C 31
GC2300iW 24/30 C 23
GC2300iW 24/30 C 31
Naar schacht: 80/125 mm
GC2300iW 19/30 C 23
In schacht: 80 mm star
GC2300iW 19/30 C 31
GC2300iW 24/30 C 23
GC2300iW 24/30 C 31
80/125 mm
GC2300iW 19/30 C 23
GC2300iW 19/30 C 31
GC2300iW 24/30 C 23
GC2300iW 24/30 C 31
Naar schacht: 80/125 mm
GC2300iW 19/30 C 23
In schacht: 80 mm star
GC2300iW 19/30 C 31
GC2300iW 24/30 C 23
GC2300iW 24/30 C 31
Naar schacht: 80/125 mm
GC2300iW 19/30 C 23
In schacht: 80 mm star
GC2300iW 19/30 C 31
GC2300iW 24/30 C 23
GC2300iW 24/30 C 31
60/100 mm
GC2300iW 19/30 C 23
GC2300iW 19/30 C 31
GC2300iW 24/30 C 23
GC2300iW 24/30 C 31
80/125 mm
GC2300iW 19/30 C 23
GC2300iW 19/30 C 31
GC2300iW 24/30 C 23
GC2300iW 24/30 C 31
80/80 mm
GC2300iW 19/30 C 23
GC2300iW 19/30 C 31
GC2300iW 24/30 C 23
GC2300iW 24/30 C 31
De lengte van de rookgasafvoerbuizen L (eventueel totaal van L
L
) is de totale lengte van de rookgasafvoer.
3
Met de benodigde bochten van een rookgasafvoer (bijvoorbeeld boch-
ten op de ketel en steunbochten in de schacht bij
lengte rekening gehouden.
• Elke extra 90°90°-bocht komt overeen met 2 m.
• Elke extra 45° of 15°-bocht komt overeen met 1 m.
Schachtdoorsnede Maximale buislengten
–
–
–
–
120x120 mm
130x130 mm
≥ 140x140 mm 24 m
140 mm
≥ 150 mm
–
–
–
Rookgasafvoer
, L
1
2
) is al in de maximale
23
L
L
L
2
3
L = L
+L
1
2
L = L
+L
+L
1
2
3
50 m
5 m
–
50 m
5 m
–
24 m
5 m
–
50 m
5 m
10 m
24 m
5 m
–
24 m
5 m
–
5 m
–
24 m
5 m
–
24 m
5 m
–
9 m
–
–
23 m
–
–
28 m
–
–
13