INSTRUCTIONS FOR INSTALLATION

Fitting the fire to an existing chimney

The fire can be fitted into an existing chimney providing
that the chimney / flue dimensions are 150 mm or more.
A special flue kit is required, which can be obtained from
Drugasar or a Drugasar agent. Do not use any other type
of flue system for this.
BS 5871 – 1 : 2001
Any chimney previously used for an appliance burning a
fuel other than gas shall be swept thoroughly before
installing any gas appliance.
Appliances shall be connected only to the types and sizes
of flue system as specified.
For any other information about this flue system please
contact Drugasar or Drugasar approved agent.

Baffle

To ensure that the appliance works satisfactorily, the baffle
should be fitted in such a way that the heater can be
adjusted according to the customer-specific pipe system.

Adjusting the baffle

The baffle plate is supplied separately and should be fitted
into the heater as indicated in fig. 6.
Use the adjustment jig provided (fig. 5) to adjust the baffle
to the right size. Once it has been adjusted, fix the damper
in place with the socket-head screw.
See the table for adjustment specifications.
Then fit the middle section of the smoke duct.
NB: the maximum length of horizontal pipe must
not be exceeded.
Fig. 4 illustrates how to calculate the total lengths of pipe.
fig. 5
G25/G20
1 m vertical + roof duct
2 - 3 m vertical + roof duct
4 - 5 m vertical + roof duct
6 - 7 m vertical + roof duct
8 - 9 mtr vertical + roof duct
10 - 12 m vertical + roof duct
1 m vertical + 90˚ bend + wall duct
1 m vertical + 90˚ bend
+ max 1 mtr horizontal + wall duct
1.2 m vertical + 90˚ bend
+ max 2 mtr horizontal + wall duct

Connecting the Gas Supply

An approved connecting tap with coupling should be used
in the supply hose (In Belgium this must be B.G.V.
approved). Furthermore:
• Expel all air from the supply pipes/hoses before coupling
to the appliance.
• Do not turn the coupling tap when connecting it to the
gas supply.
• Avoid any pressure on the control tap and pipes.
• Check that all connections are gastight.
Baffle
YES
YES
YES
YES
YES
YES
NO
NO
NO
28
Baffle
fig. 6
Distance
Inlet guides
baffle
(diagonals)
53 mm
YES
48 mm
YES
43 mm
YES
38 mm
YES
35 mm
YES
33 mm
YES
OPEN
YES
OPEN
YES
OPEN
NO