A1-04: Init Wachtwoord 1
• Deze constante wordt gereserveerd voor de fabriek om functies te testen en te wijzigen.
• Het is gebruikers niet toegestaan om deze constante in te stellen.
Lock the constants setting (A1-01=1)
1.
Finish setting all the programmable parameters to the desired values.
2.
Change A1-01=0 (Operation only), factory setting is A1-01=1 (Constant set).
3.
Go to A1-04 and press RUN/STOP key and UP key at the same time till A1-05 parameter
occurs.
4.
Enter the desired password (max. 4 digits)
5.
Press UP key to leave A1-05
Above procedure completes locking the constants setting and no more programming se-
lection would appear. A1-01 would only display 0 (Operation only) and would not display
1 (Constants set).
Unlock the constants setting
1.
Enter the password in A1-04 to be exactly the same as the one earlier set in A1-05
2.
When the password in A1-04 matches the one earlier set in A1-05, the unlocking is com-
pleted. A1-01=1 (Constants set) would appear again for programming.
3.
B Groep (Algemeen):
B1 Groep (Uitgangsfrequentie)
B1-01: Uitgangsfrequentie
• B1-01 wordt gebruikt om de uitgangsfrequentie van de INVERTER AC-uitgang in te
stellen.
Instelling
B1-01 = 0
(Initiele instelling)
B1-01 = 1
• B2-08: AC IN Frequentiebereik
Instelling
B2-08 = 0
B2-08 – 1
(Initiele instelling)
54
090138.01
50Hz op INVERTER AC-uitgang
60Hz op INVERTER AC-uitgang
Als B1-01=0: Een AC-ingangsfrequentie van 50 Hz ± 5 Hz (45 ~ 55 Hz) is accep-
tabel
Als B1-01=1: Een AC-ingangsfrequentie van 60 Hz ± 5 Hz (55 ~ 65 Hz) is accep-
tabel
Een AC-ingangsfrequentie van 45 ~ 65 Hz is acceptabel.
Functie
Functie
Batterij-lader / inverter COMBI-GAMMA