REQUEST FOR THE INDICATION OF INSTALLATION INFORMATION
1. RECORD OF INDOOR UNIT MODEL AND INSTALLATION SITE
No.
1
2
3
4
MODELNAME
INSTALLATION
SITE
No.
11
12
13
14
MODELNAME
INSTALLATION
SITE
No.
21
22
23
24
MODELNAME
INSTALLATION
SITE
No.
31
32
33
34
MODELNAME
INSTALLATION
No.
SITE
41
42
43
44
MODELNAME
INSTALLATION
SITE
No.
51
52
53
54
MODELNAME
INSTALLATION
SITE
No.
61
62
63
64
MODELNAME
INSTALLATION
SITE
2. RECORD FOR SETTINGS (CONTENTS SEE INSTALLATION MANUAL)
SETTING
VALUE
REMARK
DATE
3. RECORD OF INSTALLATION DATE
DAY
MONTH
YEAR
6. AFTER EQUIPPING, PLEASE PUT IT ON THE BACK SIDE OF THE FRONT PLATE.
f
g
1×
1×
a
Algemene voorzorgsmaatregelen met betrekking tot de
veiligheid
b
Montagehandleiding en gebruiksaanwijzing
c
Label hoeveelheid extra koelmiddel
d
Informatiesticker installatie
e
Label gefluoreerde broeikasgassen
f
Meertalig label gefluoreerde broeikasgassen
g
Zak met leidingaccessoires
11.2
Accessoireleidingen: Diameters
Accessoireleidingen
Gasleiding
▪ Aansluiting aan voorkant
ID Øa
ID Øb
▪ Aansluiting aan onderkant
ID Øa
OD Øb
Vloeistofleiding
▪ Aansluiting aan voorkant
ID Øb
ID Øa
▪ Aansluiting aan onderkant
ID Øb
ID Øa
Hogedruk-/lagedrukgasleiding
▪ Aansluiting aan voorkant
ID Øa
ID Øb
▪ Aansluiting aan onderkant
ID Øa
OD Øb
11.3
Transportbeveiliging verwijderen
(alleen voor 5~12 HP)
OPMERKING
Als
de
unit
wordt
transportbeveiliging te verwijderen, kunnen er abnormale
trillingen of geluiden worden geproduceerd.
De transportbeveiliging die de unit beschermt tijdens het transport
moet worden verwijderd. Ga te werk zoals afgebeeld en hierna
beschreven.
1 Verwijder de bout (a) en vulringen.
REMA5+REYA8~20A7Y1B
VRV 5 warmteterugwinning
4P684060-1B – 2023.07
c
d
e
1×
1×
1×
REQUEST FOR THE INDICATION OF ADDITIONAL REFRIGERANT CHARGING AND LEAK DETECTION OPERATION RESULT
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
BE SURE TO FILL OUT THE BLANKS, WHICH ARE NEEDED FOR AFTER-SALE SERVICES.
5
6
7
8
9
10
1. CALCULATION OF ADDITIONAL REFRIGERANT CHARGING AMOUNT
CALCULATE THE ADDITIONAL REFRIGERANT CHARGING AMOUNT BASED ON THE FORMULA BELOW BEFORE CHARGING.
SHIPMENT (INDICATED ON THE MACHINE NAMEPLATE) AND THE ADDITIONAL AMOUNT SHOWN AS FOLLOWS :
WHEN RE-CHARGING TOTAL AMOUNT OF REFRIGERANT , CHARGE THE TOTAL OF THE AMOUNT CHARGED AT
Total indoor unit
15
16
17
18
19
20
kg
capacity connection
Total indoor unit capacity
ratio (CR)
50%< CR < 105%
8HP
0
0
10-12HP 14-16HP 18-20HP
0
0.5
OUTDOOR
ADDITIONAL CHARGING
AMOUNT
PIPE SIZE O22.2 x 0.37
TOTAL LENGTH OF LIQUID
TOTAL LENGTH OF LIQUID
PIPE SIZE O19.1 x 0.26
PIPE SIZE O15.9 x 0.18
TOTAL LENGTH OF LIQUID
when piping length <30m
105%< CR < 130%
50%< CR < 70%
0.5
0
0.5
0
0.5
0
0.5
1.0
25
26
27
28
29
30
UNIT
kg
(m) x 0.37
(m) x 0.26
(m) x 0.18
Total indoor unit capacity
when piping length >30m
70%< CR < 85%
85%< CR < 105%
0.3
0.7
0.5
1
0.5
1
1.5
1.0
105%< CR < 130%
1.2
1.5
1.5
2.0
TOTAL LENGTH OF LIQUID
PIPE SIZE O12.7 x 0.12
PIPE SIZE O9.5 x 0.059
TOTAL LENGTH OF LIQUID
PIPE SIZE O6.4 x 0.022
TOTAL LENGTH OF LIQUID
35
36
37
38
39
40
(m) x 0.12
(m) x 0.059
(m) x 0.022
kg
RYYQ8~12
ONLY FOR RYYQ8~20 MODELS
RYYQ14-16
RYYQ18-20
0.9
1.1
1.3
2. RECORD OF ADDITIONAL REFRIGERANT CHARGE AMOUNT AND RESULT OF LEAK CHECK OPERATION
45
46
47
48
49
50
DATE
AMOUNT
55
56
57
58
59
60
RESULT LEAK CHECK
DATE
AMOUNT
RESULT LEAK CHECK
DATE
AMOUNT
SETTING
VALUE
REMARK
DATE
RESULT LEAK CHECK
DATE
AMOUNT
RESULT LEAK CHECK
3. FOR DETAILS CONCERNING PIPING SELECTION AND CALCULATION OR HOW TO OPERATE THE LEAK DETECTION FUNCTION, PLEASE REFER TO THE INSTALLATION MANUAL.
4. MODEL NAME
5. MANUFACTURING NUMBER
4. AFTER FILLING IN THIS TABLE, PLEASE PUT IT ON THE SWITCH BOX COVER.
3P328191-1
3P328192-1
HP
Øa [mm] Øb [mm]
5
25,4
19,1
8
10
12
22,2
14
16
18
20
28,6
5
9,5
9,5
8
10
12
12,7
14
12,7
16
18
20
5
19,1
15,9
8
10
12
19,1
14
16
18
20
22,2
gebruikt
zonder
eerst
2 Verwijder de transportbeveiliging (b) zoals hierna afgebeeld.
a
1
b
a
Bout
b
Transportbeveiliging
12
Over de units en opties
12.1
Over de buitenunit
Deze montagehandleiding betreft het volledig door inverter
aangedreven VRV 5-warmteterugwinningssysteem.
Verkrijgbare modellen:
Model
REYA8~20
REMA5
Welke functies beschikbaar zijn, hangt af van het type van de
geselecteerde buitenunit. Dit wordt in deze montagehandleiding
aangegeven. Sommige functies zijn exclusief voor bepaalde
modellen.
Deze
units
zijn
bedoeld
warmtepomptoepassingen, waaronder lucht/luchttoepassingen.
De verwarmingscapaciteit van deze units (bij enkelvoudig gebruik)
gaat van 25 tot 63 kW en de koelcapaciteit van 22,4 tot 56 kW. Bij
combinatie van meerdere units kan de verwarmingscapaciteit gaan
tot 90 kW en tot 80 kW voor koelen.
De
buitenunit
is
omgevingstemperatuur van –20°C WB tot 15,5°C WB en te koelen
bij een omgevingstemperatuur van –5°C DB tot 46°C DB.
12.2
Systeemlay-out
WAARSCHUWING
De installatie MOET voldoen aan de vereisten die gelden
voor deze R32-apparatuur. Zie
R32-units" [ 4 18] voor meer informatie.
INFORMATIE
De volgende afbeelding is slechts een voorbeeld en komt
de
mogelijk NIET volledig overeen met de lay-out van uw
systeem.
12 Over de units en opties
(12.3 N·m)
Beschrijving
Warmteterugwinningsmodel voor
enkelvoudig gebruik of gebruik in
combinatie
Warmteterugwinningsmodel alleen voor
gebruik in combinatie
voor
installatie
buitenshuis
ontworpen
om
te
verwarmen
"13 Speciale vereisten voor
Montagehandleiding en gebruiksaanwijzing
voor
bij
een
17